Identification of a metallothionein in Synechococcus by capillary electrophoresis hyphenated with inductively coupled plasma mass spectrometry.

نویسندگان

  • André F Lavorante
  • Maria Fernanda Giné
  • Ana Paula G Gervasio
  • Carlos E S Miranda
  • Marli F Fiore
  • Cláudia M Bellato
  • Emanuel Carrilho
چکیده

A home-made system hyphenating capillary electrophoresis with an inductively coupled plasma mass spectrometer (CE-ICP-MS) for cadmium speciation of protein-binding and free cadmium ions in solution is presented. The CE-ICP-MS interface consisted of an acrylic block with an internal volume ca. 20 microL in which a platinum electrode, a capillary column, and a connection to an ICP nebulizer were inserted. A make-up electrolyte solution containing 50 mmol L(-1) Tris-HCl buffer solution (pH 9.0) was continuously flowed through the interface to the ICP nebulizer. The separation of free Cd ions, Cd-cysteine, and Cd bounded to metallothionein (MT) isoforms from rabbit liver was carried out by capillary electrophoresis, and the analytes were detected by ICP-MS. The feasibility to isolate metallothionein compounds extracted from the cyanobacterium Synechococcus PCC7942 was demonstrated. The Cd binding proteins were induced in Synechococcus PCC7942 and further analyzed by CE ICP-MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell.

The determination of sulfur in biologically relevant samples such as metalloproteins is described. The analytical methodology used is based on robust on-line coupling between capillary electrophoresis (CE) and octopole reaction cell inductively-coupled plasma mass spectrometry (ORC-ICP-MS). Polyatomic ions that form in the plasma and interfere with the determination of S at mass 32 are minimise...

متن کامل

Detection and identification of rabbit liver metallothionein-2 subisoforms by capillary zone electrophoresis - inductively coupled plasma mass spectrometry and microbore HPLC - electrospray mass spectrometry

To date, most of works concerning metallothioneins have been referring either to the MT-fraction (as isolated by gel filtration) or to two MT-isoforms resulting from the further fractionation of the MT-fraction by anion-exchange chromatography into MT-1 (eluting first) and MT-2 (eluting second). However, a further characterization of these fractions by reversed-phase HPLC [1] and capillary zone...

متن کامل

A versatile approach for assaying in vitro metallodrug metabolism using CE hyphenated with ICP-MS.

An informative analytical method, based on commercially available capillary electrophoresis (CE), inductively coupled plasma mass spectrometry (ICP-MS) and interface units, was developed for ascertaining possible metabolic transformations of metal-based drugs. Using a novel anticancer gallium compound, it was demonstrated that the drug remains intact in the simulated intestine juice. On the con...

متن کامل

Trace metal speciation by capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry: sulfate and chloride complexes of Np(V) and Pu(V).

In the framework of nuclear waste disposal, it is very important to well understand the behavior of actinides in the presence of the common environmental inorganic ligands such as sulfate and chloride. In this work, the AnO2SO4(-) and AnO2Cl 1-1 complexes have been evidenced by capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICPMS) in perchlorate/chloride and in perch...

متن کامل

International Union of Pure and Applied Chemistry Analytical Chemistry Division Commission on Microchemical Techniques and Trace Analysis Species-selective Analysis for Metal± Biomacromolecular Complexes Using Hyphenated Techniques

Analytical chemistry of metal complexes with biomacromolecules based on the coupling of a high resolution separation technique with an element or species selective detection technique is critically discussed. The role of size-exclusion chromatography (SEC) with on-line atomic spectrometric detection is evaluated for the characterization of the metal distribution among the fractions of different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 12  شماره 

صفحات  -

تاریخ انتشار 2003