Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty.

نویسندگان

  • F A Matsen
  • J L Garbini
  • J A Sidles
  • B Pratt
  • D Baumgarten
  • R Kaiura
چکیده

The term "robot" refers to a precision mechanical device that is accurately controlled by a computer using intelligent software. The term "robotic assistance" refers to the use of such a device to aid a surgeon in the optimal conduct of a procedure, particularly one requiring specified geometrical relationships. The authors have been exploring the application of robotic assistance in situations in which accuracy and precision are required in orthopaedic surgery. The initial application concerned the planning, positioning, and orientation cuts and holes of the bone required for the femoral component of a total knee arthroplasty. A three-dimensional digitizing template allowed the surgeon to specify the desired position and orientation of the component's articular surfaces in relation to the distal femur. The robotic system used this spatial relationship, along with its knowledge of the geometry of the component selected by the surgeon, to plan the precise location of the required bone cuts and holes. Finally, the robotic assistant sequentially positioned saw and drill guides with respect to the distal femur so that the surgeon made these cuts and holes in the locations necessary for optimal component fit, position, and orientation. The robotic assistant functioned easily in the operating room environment; increased the accuracy; and decreased the time, equipment, and personnel required for the conduct of the geometrical part of this surgical procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

Radiologic Assessment of Distal Femur Cutting Angle in Varus Knee Candidates for Total Knee Arthroplasty

Background: In a total knee arthroplasty surgery the goal is to produce 90 degree angle between the knee articular lobe and the mechanical femoral line. Most orthopedic surgeons usually utilize a 5 to 7 degree for distal femoral cutting angle. In this study we will aim at clearing this question, that whether the” five-seven degree” distal femoral cutting angle supposed to be an equable spectrum...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Morphometric Assessment of the Residual Width of the Distal Hamate Articular Surface after Graft Harvest for Hemi-hamate Arthroplasty

Background: The hemi-hamate arthroplasty (HHA) can restore joint congruity and stability in chronic fracturedislocationsof the proximal interphalangeal joint (PIPJ). Purpose of this study was to compare the width of the distalhamate articular surface (DHAS) to the width of the base of the middle phalanges (P2) of the fingers. We hypothesizedthe dimensions of the width of the D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 296  شماره 

صفحات  -

تاریخ انتشار 1993