Artificial Luminal Narrowing on Contrast-Enhanced Magnetic Resonance Angiograms on an Occasion of Stent-Assisted Coiling of Intracranial Aneurysm: In Vitro Comparison Using Two Different Stents with Variable Imaging Parameters
نویسندگان
چکیده
OBJECTIVE Intracranial stenting for stent-assisted coiling of aneurysms requires adequate follow-up imaging. The aim of this in vitro study was to compare in-stent artificial luminal narrowing on contrast-enhanced MR angiograms (CE-MRA) when applying Neuroform® and Enterprise® stents for stent-assisted coiling. MATERIALS AND METHODS Two intracranial nitinol stents (Enterprise® and Neuroform®) were placed in silicon tubes and then imaged at 3 T and 1.5 T by the use of a T1-weighted three-dimensional spoiled gradient-echo sequence with minimal TR and TE. CE-MRAs were obtained by using different imaging planes, voxel sizes, and bandwidths, and with or without parallel imaging. Artificial lumen narrowing (ALN) was calculated and the results were compared. RESULTS Lower magnetic field strength, axial plane perpendicular to axis of stent, and wider bandwidth resulted in a lower ALN on CE-MRA for both stents. Larger voxel size resulted in lower ALN for Neuroform® stent. The parallel imaging acceleration factor did not affect ALN. The mean ALN was lower for Neuroform®, but it was not significant by a paired t test. CONCLUSION CE-MRA of the stented lumen of vascular phantom was partially impaired with ALN. Consequently, image plane orientation, magnetic field strength, bandwidth, and voxel size should be adjusted appropriately to reduce ALN.
منابع مشابه
Effects of Imaging Parameters on the Quality of Contrast-Enhanced MR Angiography of Cerebral Aneurysms Treated Using Stent-Assisted Coiling: A Phantom Study
PURPOSE To quantitatively investigate in vitro the effects of flip angle (FA), receiver bandwidth (BW), echo time (TE), and magnetic field strength (FS) on image noise and artifacts induced by stent-assisted coiling on contrast-enhanced MR angiography (CE-MRA) images, as a first step towards optimization of imaging parameters. METHODS A phantom simulating a cerebral aneurysm treated using ste...
متن کاملA Comparison of Magnetic Resonance Angiography Techniques for the Evaluation of Intracranial Aneurysms Treated With Stent-assisted Coil Embolization
AIM To identify the effective magnetic resonance angiography (MRA) technique to monitor intracranial aneurysms treated with stent-assisted coiling. MATERIALS AND METHODS Retrospective analysis of various MRA techniques was performed in 42 patients. Three neuroradiologists independently compared non-contrast time of flight (ncTOF) MRA of the head, contrast-enhanced time of flight (cTOF) MRA of...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملStent-Assisted Coiling of Wide-Neck Intracranial Aneurysms Using Low-Profile LEO Baby Stents: Initial and Midterm Results.
BACKGROUND AND PURPOSE Low-profile self-expandable stents were recently introduced for the treatment of wide-neck intracranial aneurysms. This study investigated the initial and midterm clinical and angiographic results of LEO Baby stent-assisted coiling in the treatment of wide-neck intracranial aneurysms. MATERIALS AND METHODS A retrospective review was performed to identify patients who we...
متن کاملEndovascular treatment of intracranial vertebral artery dissections with stent placement or stent-assisted coiling.
BACKGROUND AND PURPOSE Endovascular treatment with stent placement or stent-assisted coiling was recently introduced as an alternative to parent artery occlusion in intracranial vertebral artery dissections. We describe the efficacy and limitations of this method. METHODS Fourteen patients with intracranial vertebral artery dissection were treated with stent placement (10 patients) or stent-a...
متن کامل