Free-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration.

نویسندگان

  • Yong Chen
  • Gregory R Lee
  • Katherine L Wright
  • Chaitra Badve
  • Dean Nakamoto
  • Alice Yu
  • Mark D Schluchter
  • Mark A Griswold
  • Nicole Seiberlich
  • Vikas Gulani
چکیده

OBJECTIVES The goal of this study was to develop free-breathing high-spatiotemporal resolution dynamic contrast-enhanced liver magnetic resonance imaging using non-Cartesian parallel imaging acceleration, and quantitative liver perfusion mapping. MATERIALS AND METHODS This study was approved by the local institutional review board and written informed consent was obtained from all participants. Ten healthy subjects and 5 patients were scanned on a Siemens 3-T Skyra scanner. A stack-of-spirals trajectory was undersampled in-plane with a reduction factor of 6 and reconstructed using 3-dimensional (3D) through-time non-Cartesian generalized autocalibrating partially parallel acquisition. High-resolution 3D images were acquired with a true temporal resolution of 1.6 to 1.9 seconds while the subjects were breathing freely. A dual-input single-compartment model was used to retrieve liver perfusion parameters from dynamic contrast-enhanced magnetic resonance imaging data, which were coregistered using an algorithm designed to reduce the effects of dynamic contrast changes on registration. Image quality evaluation was performed on spiral images and conventional images from 5 healthy subjects. RESULTS Images with a spatial resolution of 1.9 × 1.9 × 3 mm3 were obtained with whole-liver coverage. With an imaging speed of better than 2 s/vol, free-breathing scans were achieved and dynamic changes in enhancement were captured. The overall image quality of free-breathing spiral images was slightly lower than that of conventional long breath-hold Cartesian images, but it provided clinically acceptable or better image quality. The free-breathing 3D images were registered with almost no residual motion in liver tissue. After the registration, quantitative whole-liver 3D perfusion maps were obtained and the perfusion parameters are all in good agreement with the literature. CONCLUSIONS This high-spatiotemporal resolution free-breathing 3D liver imaging technique allows voxelwise quantification of liver perfusion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.

PURPOSE The purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). MATERIALS AND METHODS In this ins...

متن کامل

Accelerating time-resolved MRA with multiecho acquisition.

A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...

متن کامل

Use of Parallel Imaging in Peripheral Contrast-enhanced Magnetic Resonance Angiography: Retrospective Study

Objective: To evaluate the application of a parallel imaging technique — generalised autocalibrating partially parallel acquisition — in peripheral contrast-enhanced magnetic resonance angiography. Patients and Methods: This was a retrospective review of 17 consecutive patients with peripheral vascular disease who underwent lower-extremity 3-dimensional contrast-enhanced magnetic resonance angi...

متن کامل

Magnetic Resonance in Medicine 63:502–509 (2010) IIR GRAPPA for Parallel MR Image Reconstruction

Accelerated parallel MRI has advantage in imaging speed, and its image quality has been improved continuously in recent years. This paper introduces a two-dimensional infinite impulse response model of inverse filter to replace the finite impulse response model currently used in generalized autocalibrating partially parallel acquisitions class image reconstruction methods. The infinite impulse ...

متن کامل

Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging.

BACKGROUND AND PURPOSE Diffusion tensor magnetic resonance imaging (DTI) of the brain is usually acquired with single-shot echo-planar imaging, which is associated with localized signal loss, geometric distortions, and blurring. Parallel imaging can lessen these artifacts by shortening the length of the echo-train acquisition. The self-calibrating parallel acquisition techniques, image domain-b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative radiology

دوره 50 6  شماره 

صفحات  -

تاریخ انتشار 2015