Diagnostic accuracy of Xpert MTB/RIF for tuberculosis detection in different regions with different endemic burden: A systematic review and meta-analysis

نویسندگان

  • Shiying Li
  • Bin Liu
  • Mingli Peng
  • Min Chen
  • Wenwei Yin
  • Hui Tang
  • Yuxuan Luo
  • Peng Hu
  • Hong Ren
چکیده

PURPOSE To estimate the diagnostic accuracy of Xpert MTB/RIF, a systematic review and meta-analysis were carried out. METHODS Up to June 20, 2015, multiple databases were screened for relevant studies. RESULTS Accordingly, 106 studies included 52,410 samples were selected. Diagnostic accuracy of Xpert MTB/RIF for TB detection was validated against either culture or a composite reference standard (CRS). Additionally, selected studies were further subgrouped in four groups based on sample's type, subject's age, status of HIV co-infection and smear-positivity. The overall pooled sensitivity and specificity of Xpert MTB/RIF was 0.85 (95% confidence interval [CI] 0.82-0.88) and 0.98 (95% CI 0.96-0.98), respectively, compared to culture; while it was 0.59 (95% CI 0.44-0.72) and 0.99 (95% CI 0.97-1.00) compared to CRS. The overall sensitivity was lower in countries with high TB prevalence than countries with middle/low prevalence (0.84, 95% CI: 0.80-0.88 versus 0.89, 95% CI: 0.84-0.93). Furthermore, Xpert MTB/RIF has higher sensitivity in patients with positive smears (0.99, 95% CI 0.97-0.99), in patients with pulmonary TB samples (0.87, 95% CI 0.83-0.90), in adults (0.82, 95% CI 0.76-0.86) and in HIV-positive patients (0.81, 95% CI 0.73-0.87). CONCLUSIONS Taken together, Xpert MTB/RIF is a quick and accurate diagnostic assay for TB which will significantly help the physicians to make their clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Xpert MTB/RIF assay for the diagnosis of extrapulmonary tuberculosis: a systematic review and meta-analysis.

Xpert MTB/RIF (Cepheid, Sunnyvale, CA, USA) is endorsed for the detection of pulmonary tuberculosis (TB). We performed a systematic review and meta-analysis to assess the accuracy of Xpert for the detection of extrapulmonary TB. We searched multiple databases to October 15, 2013. We determined the accuracy of Xpert compared with culture and a composite reference standard (CRS). We grouped data ...

متن کامل

Rapid and effective diagnosis of tuberculosis and rifampicin resistance with Xpert MTB/RIF assay: a meta-analysis.

OBJECTIVES Xpert MTB/RIF (Cepheid) assay has been introduced for the diagnosis of tuberculosis (TB) and RIF-resistance. The meta-analysis was used to establish the overall accuracy of Xpert MTB/RIF assay for diagnosing TB and RIF-resistance. METHODS Based on comprehensive searches of the Pubmed and Embase, we identified outcome data from all articles estimating diagnostic accuracy with Xpert ...

متن کامل

Advances in tuberculosis diagnostics: the Xpert MTB/RIF assay and future prospects for a point-of-care test.

Rapid progress has been made in the development of new diagnostic assays for tuberculosis in recent years. New technologies have been developed and assessed, and are now being implemented. The Xpert MTB/RIF assay, which enables simultaneous detection of Mycobacterium tuberculosis (MTB) and rifampicin (RIF) resistance, was endorsed by WHO in December, 2010. This assay was specifically recommende...

متن کامل

Rapid diagnosis of tuberculosis using Xpert MTB/RIF assay - Report from a developing country

OBJECTIVE To evaluate the diagnostic accuracy of the Xpert MTB/RIF assay for the detection of M. tuberculosis in pulmonary and extrapulmonary specimens and to compare it with conventional techniques. METHODS During a period of 10 months from December 2012 through September 2013, two hundred and forty five clinically TB suspects were enrolled for Xpert MTB\RIF assay. The cohort comprised of 20...

متن کامل

Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice

The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017