Ejection load changes in aortic stenosis. Observations made after balloon aortic valvuloplasty.

نویسندگان

  • Y Shim
  • T G Hampton
  • C A Straley
  • J K Harrison
  • L A Spero
  • T M Bashore
  • A D Pasipoularides
چکیده

To investigate complementarity and competitiveness between the intrinsic and extrinsic components of the total left ventricular systolic load, hemodynamic data from 18 elderly subjects with severe aortic stenosis were analyzed before and after balloon dilation of the stenosed aortic valve. Multisensor micromanometric pressure measurements allowed calculation (simplified Bernoulli equation) of the ejection velocity and aortic input impedance spectra. Despite a 32% increase in the aortic valve area (from 0.56 +/- 0.04 to 0.74 +/- 0.05 cm2 [mean +/- SEM], p < 0.01), the peak left ventricular systolic pressure fell by only 12% (from 189 +/- 10 to 167 +/- 8 mm Hg, p < 0.01). This was accompanied by an increase in the impedance at the same cardiac output. In a subset of patients (n = 9) in whom the peak aortic systolic pressure rose after valvuloplasty (from 115 +/- 10 to 128 +/- 12 mm Hg, p < 0.01), a 40% increase in the aortic valve area was accompanied by a marked increase in the aortic input impedance. In this subset, the steady component of the aortic input impedance increased by 24% (from 960 +/- 96 to 1,188 +/- 134 dyne.sec/ml, p < 0.05), and the characteristic impedance increased by 25% (from 106 +/- 13 to 132 +/- 19 dyne.sec/ml, p < 0.05). Because of an increased aortic impedance acutely following the procedure, the total left ventricular systolic load after balloon dilation of the stenotic valve was only slightly decreased despite a significant increase in aortic valve area. This represents an example of complementarity and competitiveness between the intrinsic and extrinsic components of the total systolic ventricular load. It may explain why improvement in left ventricular performance may be modest acutely following balloon aortic valvuloplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی

Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

Improvement in symptoms and left ventricular performance after balloon aortic valvuloplasty in patients with aortic stenosis and depressed left ventricular ejection fraction.

The application of balloon aortic valvuloplasty to elderly patients with severe aortic stenosis and a low ventricular ejection fraction is undefined. Balloon aortic valvuloplasty was performed in a subset of 28 patients with low left ventricular ejection fraction (37 +/- 11%), severe aortic stenosis, and a mean age of 79 +/- 5 years. After valvuloplasty, significant increases were seen in aorti...

متن کامل

Ascending aortic approach for balloon aortic valvuloplasty with concomitant bilateral pulmonary artery banding in a very low-birth-weight neonate with critical aortic stenosis and poor left ventricular function.

An 1186-g infant was born at 27 weeks' gestation. Echocardiography showed critical aortic stenosis, a dilated left ventricle (left ventricular end-diastolic diameter, 16.9 mm), and poor left ventricular function (left ventricular ejection fraction, 8.5%). Due to duct-dependent systemic circulation, the patient underwent a hybrid intervention consisting of bilateral pulmonary artery banding (PAB...

متن کامل

Balloon aortic valvuloplasty: results of the Valvuloplasty and Angioplasty of Congenital Anomalies Registry.

Data from 204 children and infants who underwent aortic balloon valvuloplasty between 1982 and 1986, reported to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry, were reviewed. Valvuloplasty was successful in 192 of 204 children, reducing the peak systolic left ventricular ejection gradient from 77 +/- 2 to 30 +/- 1 mm Hg, p less than 0.001. The same degree of aortic stenosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 71 5  شماره 

صفحات  -

تاریخ انتشار 1992