Quantitative microbial risk assessment of distributed drinking water using faecal indicator incidence and concentrations.
نویسندگان
چکیده
Quantitative Microbial Risk Assessments (QMRA) have focused on drinking water system components upstream of distribution to customers, for nominal and event conditions. Yet some 15-33% of waterborne outbreaks are reported to be caused by contamination events in distribution systems. In the majority of these cases and probably in all non-outbreak contamination events, no pathogen concentration data was available. Faecal contamination events are usually detected or confirmed by the presence of E. coli or other faecal indicators, although the absence of this indicator is no guarantee of the absence of faecal pathogens. In this paper, the incidence and concentrations of various coliforms and sources of faecal contamination were used to estimate the possible concentrations of faecal pathogens and consequently the infection risks to consumers in event-affected areas. The results indicate that the infection risks may be very high, especially from Campylobacter and enteroviruses, but also that the uncertainties are very high. The high variability of pathogen to thermotolerant coliform ratios estimated in environmental samples severely limits the applicability of the approach described. Importantly, the highest ratios of enteroviruses to thermotolerant coliform were suggested from soil and shallow groundwaters, the most likely sources of faecal contamination that are detected in distribution systems. Epidemiological evaluations of non-outbreak faecal contamination of drinking water distribution systems and thorough tracking and characterisation of the contamination sources are necessary to assess the actual risks of these events.
منابع مشابه
Estimation of pathogen concentrations in a drinking water source using hydrodynamic modelling and microbial source tracking.
The faecal contamination of drinking water sources can lead to waterborne disease outbreaks. To estimate a potential risk for waterborne infections caused by faecal contamination of drinking water sources, knowledge of the pathogen concentrations in raw water is required. We suggest a novel approach to estimate pathogen concentrations in a drinking water source by using microbial source trackin...
متن کاملFungi Occurrence Assessment in Drinking Water Distribution Systems and Its Relationship with Fecal Indicator Bacteria
Introduction: As recommended by World Health Organization, consumption of the fungal contaminated water does not cause to serious infection, but may lead to healthy or aesthetic problems. The aim of this research was to assess the occurrence of fungi in water and its relationship with fecal indicator bacteria. Materials and Methods: 110 water samples were collected from different location of w...
متن کاملDecay Rates of Faecal Indicator Organisms and Pathogens: Use of Microcosm and In Situ Studies for the Estimation of Exposure Risk in Recreational Waters
This three year study compared the decay of the commonly used faecal indicator organisms Escherichia coli, enterococci and coliphage in coastal water and sediment using laboratory based microcosms with that for the pathogens Salmonella typhimurium and S. derby. Results from the laboratory study were validated with in-situ decay rates of faecal coliforms observed at a recreational coastal site f...
متن کاملA Survey on Drinking Water Contamination to Indicator Bacteria in Dairy Farms of Mashhad Suburb
BACKGROUND: Microbial quality of drinking water is very important in animal health. OBJECTIVES: The present survey was conducted to evaluate the microbial quality of cows' drinking water in dairy farms in Mashhad suburb, Iran, to find out defects in this field. METHODS: Water samples were taken from 30 farms and 4 sites including: Water tanks, inlet and outlet of bovine drinking troughs and c...
متن کاملتعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN
Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of water and health
دوره 5 Suppl 1 شماره
صفحات -
تاریخ انتشار 2007