The relationship between single-breath diffusion capacity of the lung for nitric oxide and carbon monoxide during various exercise intensities.

نویسندگان

  • Gerald S Zavorsky
  • Karine Badra Quiron
  • Philip S Massarelli
  • Larry C Lands
چکیده

STUDY OBJECTIVES To determine the relationship between single-breath diffusion capacity of the lung for nitric oxide (DLNO) and single-breath diffusion capacity of the lung for carbon monoxide (DLCO), and to determine the single-breath DLNO/DLCO ratios during rest and at several exercise intensities using a commercial lung diffusion system that uses electrochemical cells to analyze gases. SETTING AND PARTICIPANTS Eight healthy men (age, 27 +/- 5 years; weight, 83.0 +/- 11.8 kg; height, 180.4 +/- 9.5 cm; maximal oxygen uptake [VO(2)max], 47.6 +/- 10.2 mL/kg/min [mean +/- SD]) performed single-breath DLNO measurements (inspired nitric oxide concentration, 66.5 +/- 10.6 ppm) and carbon monoxide (0.30%) randomized on different days at rest and at various exercise intensities (40%, 75%, and 90% of VO(2)max reserve [VO(2)R]) on a electrically braked load simulator. The DLCO measured on day 1 was compared to the DLCO measured during the DLNO method from another day. RESULTS The relationship between DLNO and DLCO was linear (DLNO = 4.47 x DLCO; r(2) = 0.91; standard error of the estimate = 0.04; p < 0.05). DLNO was 4.52 +/- 0.24 times greater than DLCO, independent of exercise intensity. DLNO increased from 210.3 +/- 18.2 mL/min/mm Hg at rest to 284.2 +/- 38.6 mL/min/mm Hg at 90% VO(2)R (oxygen uptake = 42.6 +/- 9.8 mL/kg/min; 284.2 +/- 31.6 W; p < 0.05). Stepwise regression demonstrated that DLNO is predicted by alveolar volume (VA) [in liters] and workload (watts) such that DLNO = 13.4 x VA + 0.23 x workload + 107.7 (r(2) = 0.90; SEE = 17.5; p < 0.05). CONCLUSION (1) Single-breath DLNO and DLCO increase linearly with increasing workload; (2) the single-breath DLNO/DLCO ratios are independent of exercise intensity, suggesting that using either nitric oxide or carbon monoxide as transfer gases are valid in the study of lung diffusion during any level of exercise; and (3) DLNO is mainly predicted by VA and workload.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A small amount of inhaled nitric oxide does not increase lung diffusing capacity Gerald

Purpose: To determine (a) whether 40-50 ppm nitric oxide increases lung diffusing capacity for nitric oxide (DLNO) and carbon monoxide (DLCO), membrane diffusing capacity for CO (DmCO) and pulmonary capillary blood volume (Vc); (b) the actual number of tests required to provide a reasonable estimate of DLNO, DLCO, DmCO, and Vc; (c) repeatability of these parameters using the single-breath DLNO–...

متن کامل

A small amount of inhaled nitric oxide does not increase lung diffusing capacity.

The aim of the present study was to determine: 1) whether 40-50 ppm nitric oxide (NO) increases diffusing capacity of the lung for NO (D(L,NO)) and carbon monoxide (D(L,CO)), membrane diffusing capacity for CO (D(m,CO)) and pulmonary capillary blood volume (V(c)); 2) the actual number of tests required to provide a reasonable estimate of D(L,NO), D(L,CO), D(m,CO) and V(c); and 3) repeatability ...

متن کامل

Determination of lung capillary blood volume and membrane diffusing capacity in patients with COLD using the NO-CO method.

Lung capillary blood volume (Qc) and the membrane diffusing capacity (Dm) can both be determined from the combined measurement of nitric oxide (NO) and carbon monoxide (CO) transfers using the single-breath method. In ten healthy subjects, no differences was observed between the values of transfer factor of the lungs for carbon monoxide (TLCO) recovered after a 3 s or 9 s breath-holding time (t...

متن کامل

A simultaneous single breath measurement of pulmonary diffusing capacity with nitric oxide and carbon monoxide.

Pulmonary diffusing capacity (DL) for carbon monoxide (CO) and nitric oxide (NO) were simultaneously measured in man using the single breath method, by adding 4O ppm of NO to the inspired gas and analysing the expirate for NO by a chemiluminescent method. The mean ratio of DLNO to DLCO in thirteen subjects was 4.3 (SD 0.3), mean DLNO = 49 mmol.min-1.kPa-1 (SD 10) and mean DLCO = 11 mmol.min-1.k...

متن کامل

Improvement in lung diffusion by endothelin A receptor blockade at high altitude.

Lung diffusing capacity has been reported variably in high-altitude newcomers and may be in relation to different pulmonary vascular resistance (PVR). Twenty-two healthy volunteers were investigated at sea level and at 5,050 m before and after random double-blind intake of the endothelin A receptor blocker sitaxsentan (100 mg/day) vs. a placebo during 1 wk. PVR was estimated by Doppler echocard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 125 3  شماره 

صفحات  -

تاریخ انتشار 2004