Influence of Paralleled Capacitance Effect in Well-defined Multiple Value Logical Level System with Active Load

نویسندگان

  • Chin Yang
  • Yen Chun Lin
  • Hsiao Hsuan Cheng
چکیده

Three similar negative differential resistance (NDR) profiles with both high peak to valley current density ratio (PVCDR) value and high peak current density (PCD) value in unity resonant tunneling electronic circuit (RTEC) element is developed in this paper. The PCD values and valley current density (VCD) values of the three NDR curves are all about 3.5 A and 0.8 A, respectively. All PV values of NDR curves are 0.40 V, 0.82 V, and 1.35 V, respectively. The VV values are 0.61 V, 1.07 V, and 1.69 V, respectively. All PVCDR values reach about 4.4 in three NDR curves. The PCD value of 3.5 A in triple PVCDR RTEC element is better than other resonant tunneling devices (RTD) elements. The high PVCDR value is concluded the lower VCD value about 0.8 A. The low VCD value is achieved by suitable selection of resistors in triple PVCDR RTEC element. The low PV value less than 1.35 V possesses low power dispersion in triple PVCDR RTEC element. The designed multiple value logical level (MVLL) system using triple PVCDR RTEC element provides equidistant logical level. The logical levels of MVLL system are about 0.2 V, 0.8 V, 1.5 V, and 2.2 V from low voltage to high voltage and then 2.2 V, 1.3 V, 0.8 V, and 0.2 V from high voltage back to low voltage in half cycle of sinusoid wave. The output level of four levels MVLL system is represented in 0.3 V, 1.1 V, 1.7 V, and 2.6 V, which satisfies the NMP condition of traditional two-bit system. The remarkable logical characteristic of improved MVLL system with paralleled capacitor are with four significant stable logical levels about 220 mV, 223 mV, 228 mV, and 230 mV. The stability and articulation of logical levels of improved MVLL system are outstanding. The average holding time of improved MVLL system is approximately 0.14 μs. The holding time of improved MVLL system is fourfold than of basic MVLL system. The function of additional capacitor in the improved MVLL system is successfully discovered. Keywords—Capacitance, Logical level, Constant current source

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Introduction of proper model of land slide relationship on sediment in GolGol basin system

Extended abstract 1- Introduction       Investigating the relationship between landslides in sediment production in watersheds is one of the most important issues in the management of watersheds. The purpose of this research is to introduce a suitable model for the effect of landslide on sediment load in Gol Gol watershed in Ilam province, with the assumption that the linear relationship betw...

متن کامل

The Effect of High Penetration Level of Distributed Generation Sources on Voltage Stability Analysis in Unbalanced Distribution Systems Considering Load Model

Static voltage stability is considered as one of the main issues for primary identification before voltage collapsing in distribution systems. Although, the optimum siting of distributed generation resources in distribution electricity network can play a significant role in voltage stability improving and losses reduction, the high penetration level of them can lead to reduction in the improvem...

متن کامل

Assessing the Impact of Size and Site of DGs and SMs in Active Distribution Networks for Energy Losses Cost

The presence of responsive loads in the promising active distribution networks (ADNs) would definitely affect the power system problems such as distributed generations (DGs) studies. Hence, an optimal procedure is proposed herein which takes into account the simultaneous placement of DGs and smart meters (SMs) in ADNs. SMs are taken into consideration for the sake of successful implementing of ...

متن کامل

Control and stability improvement of combined wind-battery system with permanent magnet synchronous generator supplying active load

This paper deals with the control and stability enhancement of a wind power generation system feeding active load with constant power characteristic. The under study system is a combined wind-battery generation system with permanent magnet synchronous generator (PMSG) supplying active load by using interfaced power electronics converters. The employed active load is indeed an active rectifier b...

متن کامل

Explicit Logical Effort Formulation for Minimum Active Area under Delay Constraints

This paper presents a gate sizing method which formulates minimum active area solutions under delay constraints. It is based on the logical effort delay model. Such minimization of transistor widths has direct impact on the power consumption and circuit area reduction. The explicit formulation of the method takes into account the maximum input capacitance, the output load to be driven, and the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013