Comparison of International Normalized Ratio Measurement between CoaguChek XS Plus and STA-R Coagulation Analyzers
نویسندگان
چکیده
BACKGROUND Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting. We investigated whether the prothrombin time international normalized ratio (INR) results by CoaguChek XS Plus (Roche Diagnostics GmbH, Mannheim, Germany) can be used reliably without being confirmed with the INR results by STA-R system (Diagnostica Stago S.A.S, Asnières sur Seine, France). METHODS A total of 118 INR measurements by CoaguChek XS Plus and STA-R were compared using Passing/Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurements was further assessed in relation to dosing decision. RESULTS The correlation of INR measurements between CoaguChek XS Plus and STA-R was excellent (correlation coefficient = 0.964). The mean difference tended to increase as INR results increased and was 0.25 INR in the therapeutic range (2.0-3.0 INR). The overall agreement was fair to good (kappa = 0.679), and 21/118 (17.8%) INR measurements showed a difference in dosing decision. CONCLUSION The positive bias of CoaguChek XS Plus may be obvious even in the therapeutic INR range, and dosing decision based on the CoaguChek XS Plus INR results would be different from that based on the STA-R results. The INR measurements by POCT coagulometers still need to be confirmed with the laboratory INR measurements.
منابع مشابه
Accuracy of capillary whole blood international normalized ratio on the CoaguChek S, CoaguChek XS, and i-STAT 1 point-of-care analyzers.
We evaluated the accuracy of capillary whole blood international normalized ratio (INR) on the CoaguChek S (Roche Diagnostics, Indianapolis, IN), CoaguChek XS (Roche Diagnostics), and i-STAT 1 (i-STAT, East Windsor, NJ) point-of-care (POC) analyzers compared with venous plasma INRs determined by a reference laboratory method. Overall agreement between POC and laboratory plasma INR was very good...
متن کاملSelf-monitoring of oral anticoagulation therapy in children.
This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...
متن کاملEvaluation of the Roche CoaguChek XS handheld coagulation analyzer in a cardiac outpatient clinic.
This study evaluated the performance of a handheld coagulation analyzer for measurements of capillary blood specimens of 93 outpatient cardiology patients with atrial fibrillation who were receiving oral anti-coagulant therapy. The international normalized ratio (INR) results of the CoaguChek XS system (Roche Diagnostics) were compared with those obtained in the central laboratory with citrated...
متن کاملClinical Utility and Accuracy of Coaguchek XS, a Reliable Alternative to Laboratory International Normalized Ratio Monitoring in Korean Patients With Atrial Fibrillation
Background and Objectives: To evaluate the accuracy and the clinical utility of the Coaguchek XS, a portable point-of-care coagulometer, compared to standard laboratory methods in Korean patients. Subjects and Methods: We included 107 patients with atrial fibrillation on long-term oral warfarin therapy. The prothrombin time as expressed by the international normalized ratio (INR) was measured b...
متن کاملTitle: Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring Running title: Evaluation of the CoaguChek XS
Aim: To evaluate the accuracy of the CoaguChek XS international normalised ratio (INR) monitor compared to the laboratory method. Methods: The accuracy and ease of use of the recently marketed CoaguChek XS portable INR monitor was evaluated in 17 patients involved in a trial of warfarin home-monitoring. INR results from the monitor were compared to the laboratory method. Clinical applicability ...