Percutaneous intervention for recurrent aortic insufficiency in a patient with a left ventricular assist device and a centrally oversewn aortic valve.

نویسندگان

  • Raymond Bietry
  • Leora B Balsam
  • Muhamed Saric
  • Doff B McElhinney
  • Stuart Katz
  • Abe Deanda
  • Alex Reyentovich
چکیده

A 76-year-old man with severe degenerative aortic stenosis, coronary artery disease, and progressive congestive heart failure with severe systolic dysfunction underwent implantation of a Heartmate II left ventricular assist device (LVAD; Thoratec Corporation, Pleasanton, CA) after developing refractory cardiogenic shock. Because there was moderate aortic insufficiency (AI), the aortic valve was closed with a pledgeted central coaptation stitch that approximated the Noduli of Arantius with minimal residual regurgitation. After initial clinical improvement, by 5 months after LVAD implantation, the patient was hospitalized with recurrent heart failure symptoms. Echocardiography revealed new onset moderate to severe AI with 2 dominant jets that were present during systole and diastole (Video I in the online-only Data Supplement, Figure). Over the next several months he developed worsening heart failure symptoms (class IIIb) with no evidence of LVAD malfunction. Concomitantly, his left ven-tricular end diastolic dimension increased from 4.3 cm to 5.8 cm. Right heart catheterization revealed a pulmonary capillary wedge pressure of 20 mm Hg with a cardiac index of 2.6 L/ min. Surgical correction, including aortic valve replacement and closure of the left ventricular outflow tract were considered ; however, because of the patient's advanced age and 2 prior sternotomies, percutaneous closure of the aortic valve was pursued. A 2-dimensional and 3-dimensional transesophageal echocardiography was used to deploy a 6 mm Amplatzer septal occluder device (St. Jude Medical, St. Paul, MN) between the left-and noncoronary cusps of the over-sewn aortic valve. A second 5 mm Amplatzer device was deployed between the left-and right-coronary cusps of the aortic valve (Video II in the online-only Data Supplement). There was immediate improvement in the severity of aortic insufficiency after the procedure (Video III in the online-only Data Supplement). Five months after the procedure the patient has only trace AI with class II heart failure symptoms and has been free of further heart failure hospitalizations. He has moderate hemo-lysis (lactate dehydrogenase preprocedure 195 IU/L and post-procedure 457 IU/L; normal reference range 98–192 IU/L) but his hemoglobin remains >10 g/dL and stable. A growing number of patients with AI have undergone concomitant aortic valve surgery at the time of LVAD implantation to eliminate valvular insufficiency. 1 These concomitant procedures include patch closure of the left ventricular outflow tract, replacement of the aortic valve with a bioprosthesis, or closure of the aortic valve with a central coaptation stitch. Little is known about the durability of these strategies, and in the …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful percutaneous trans-catheter treatment of left ventricular assist device outflow graft stenosis with a covered stent

Left ventricular assist devices improve survival in patients with advanced heart failure but can be associated with significant complication including infection, pump thrombosis, and de novo severe aortic insufficiency. Outflow graft stenosis is a much more rare complication, but one with significant hemodynamic consequences. Surgical repair is often necessary, but many patients are too high ri...

متن کامل

گزارش 3 بیمار مبتلا به تونل آئورت به بطن چپ

Aorto-left ventricular tunnel (ALVT) is a rare congenital anomaly in which an abnormal communication connects the ascending aorta with the left ventricle, that results volume overload on left ventricle. It is clinically undistinguishable from aortic insufficiency. Its prompt and precise diagnosis is crucial since early surgical treatment is definitely indicated. In this report clinical,...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Concomitant transapical mitral valvuloplasty and CentriMag assist device placement: in a "no-option" patient.

Left ventricular assist devices and percutaneous valve interventions have radically changed the treatment of advanced heart disease and minimized surgical morbidity in patients with end-stage heart failure who would not survive conventional surgery. We describe a successful approach to the simultaneous placement of a percutaneous left ventricular assist device and mitral valvuloplasty in a deco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013