A case study: surface contamination of cyclophosphamide due to working practices and cleaning procedures in two Italian hospitals.

نویسندگان

  • Antonio Acampora
  • Loredana Castiglia
  • Nadia Miraglia
  • Maria Pieri
  • Claudio Soave
  • Francesco Liotti
  • Nicola Sannolo
چکیده

The efficacy of preventive and organisational measures implemented in Italy to prevent the contamination of cytotoxic drug preparation rooms has been investigated, and oncologic wards of two Italian hospitals were examined. The sampling strategy was based not only on potential sources of contamination but also on responses to detailed questionnaires on workplace practices and work organisation. Wipe samples were taken from different surfaces of preparation rooms, before and after the work shift, over a span of a month. Cyclophosphamide was taken as the marker drug that reflects exposure to cytotoxic drugs, being measurable by GC/MS. In one of the two hospitals (Hospital A), a large amount of cyclophosphamide was found, both before and after shift, on the workbench (median value, 2.55 microg dm(-2), before shift), on the floor between the operator working position and the waste bin (>10 microg dm(-2), after shift), as also on door handles and storage shelves. No quantifiable levels of cytotoxic drug were detected in the second hospital investigated (Hospital B). These results could be attributed to the efficacy of cleaning procedures and working practices. In fact, both hospitals were provided with vertical-laminar airflow hoods and the (male) nurses had attended special training courses; but in Hospital A, cleaning procedures were carried out without substances used specifically for the cleaning of surfaces contaminated by cytotoxic drugs such as sodium hypochlorite. Working practices did not include Luer Lock devices. Cyclophosphamide concentrations found in both hospitals, compared with the quantities of drug handled, gave evidence of the importance of the correct handling of cytotoxic agents as a major tool in reducing contamination levels. The results reveal the insufficiency of the risk management measures which do not take into account working practices that are prevailing, and stress the necessity for periodic environmental monitoring, indispensable for evolving effective procedures to prevent antineoplastic drug exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental Monitoring of Occupational Exposure to Cyclophosphamide Drug in Two Iranian Hospitals

Background: Most cytotoxic drugs are unable to discriminate normal cells from cancer cells and they interfere with cell division and could lead to harmful effects such as carcinogenicity, genetic mutation, and teratogenicity. In order to assess dermal occupational exposure to cytotoxic drugs, surface sampling was used to determine the residual drugs on the working surfaces, as well as the effec...

متن کامل

Disinfection and general cleaning practices used in health care centers and hospitals

Improving cleaning and disinfection performance must be taken into account for prevention and control of infection. Health care settings are engaged in a battle against healthcare associated infection (HAIs). The importance of infection prevention and control is increasing due to rapidly developing strains of multi-drug resistant organisms (MDROs) that can result in serious illness and even dea...

متن کامل

Evaluating the Cleaning Program Efficacy in ICU Ward of General Hospital Using Visual and Microbial Approaches

Background & Aims of the Study: Hospital infectious is one of the major causes of mortality among the hospitalized cases. The interior environment status of hospitals has the important rule in microbial transmission.  Translocation of the infectious agents may be essentially due to contacts between patients and contaminated interior environment. This work was performed to ...

متن کامل

بررسی آلودگی سطوح با داروهای سیکلوفسفامید و ایفسفامید در مراکز کموتراپی

  Background and purpose: Cyclophosphamide and ifosfamide are two most widely used and hazardous drugs in chemotherapy centers. This study aimed at determining surface contamination with cyclophosphamide and iphosphamide in chemotherapy centers. Materials and methods: This descriptive cross-sectional study was carried out in three chemotherapy centers affiliated with Hamedan University o...

متن کامل

Antineoplastic drugs contamination of workplace surfaces in two Portuguese hospitals.

Despite the classification as known or suspected human carcinogens, by the International Agency for Research on Cancer, the antineoplastic drugs are extensively used in cancer treatment due to their specificity and efficacy. As human carcinogens, these drugs represent a serious threat to the healthcare workers involved in their preparation and administration. This work aims to contribute to bet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 49 7  شماره 

صفحات  -

تاریخ انتشار 2005