Incomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the management of incomplete stent apposition.
نویسندگان
چکیده
BACKGROUND Lack of re-endothelialization and neointimal coverage on stent struts has been put forward as the main underlying mechanism leading to late stent thrombosis. Incomplete stent apposition (ISA) has been observed frequently in patients with very late stent thrombosis after drug eluting stent implantation, suggesting a role of ISA in the pathogenesis of this adverse event. The aim of this study was to evaluate the impact of different degrees of ISA severity on abnormal shear rate and healing response with coverage, because of its potential implications for stent optimization in clinical practice. METHODS AND RESULTS We characterized flow profile and shear distribution in different cases of ISA with increasing strut-wall detachment distance (ranging from 100 to 500 μm). Protruding strut and strut malapposed with moderate detachment (ISA detachment distance <100 μm) have minimal disturbance to blood flow as compared with floating strut that has more significant ISA distance. In vivo impact on strut coverage was assessed retrospectively using optical coherence tomography evaluation on 72 stents (48 patients) sequentially at baseline and after 6-month follow-up. Analysis of coverage revealed an important impact of baseline strut-wall ISA distance on the risk of incomplete strut coverage at follow-up. Malapposed segments with an ISA detachment <100 μm at baseline showed complete strut coverage at follow-up, whereas segments with a maximal ISA detachment distance of 100 to 300 μm and >300 μm had 6.1% and 15.7% of their struts still uncovered at follow-up, respectively (P<0.001). CONCLUSIONS Flow disturbances and risk of delayed strut coverage both increase with ISA detachment distance. Insights from this study are important for understanding malapposition as a quantitative, rather than binary phenomenon (present or absent) and to define the threshold of ISA detachment that might benefit from optimization during stent implantation.
منابع مشابه
The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.
OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...
متن کاملNeointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography
OBJECTIVE To analyse the neointimal coverage of sirolimus-eluting stent (SES) and bare-metal stent (BMS) visualised in vivo by optical coherence tomography (OCT). METHODS OCT images were obtained in 26 coronary vessels of 24 patients at 5-93 months after SES or BMS deployment. The short-term BMS group (BMS1) consisted of eight BMS in seven patients at 5-10 months of follow-up, the long-term B...
متن کاملStanding on solid ground?: Reassessing the role of incomplete strut apposition in drug-eluting stents.
Standing on Solid Ground?: Reassessing the Role of Incomplete Strut Apposition in Drug-Eluting Stents Antonios Karanasos, MD; Evelyn Regar, MD, PhD · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6 Living in the Readmission Era Karl E. Minges, MPH; Jeptha P. Curtis, MD · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·...
متن کاملOptical coherence tomography findings in lesions after sirolimus-eluting stent implantation with peri-stent contrast staining.
BACKGROUND We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. METHODS AND RESULTS Between May 2008 an...
متن کاملIncomplete stent apposition: should we appose or oppose?
ncomplete stent apposition (ISA), also known as stent alapposition, is defined most simplistically as the absence f contact between stent struts and the vessel wall not verlying a side branch. Incomplete stent apposition can ccur at the time of stent implantation—acute ISA—which ight either resolve or persist at follow-up (late-persistent SA). Patients without ISA at the time of stent implantai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2014