Complexation-Based Detection of Nickel(II) at a Graphene-Chelate Probe in the Presence of Cobalt and Zinc by Adsorptive Stripping Voltammetry
نویسندگان
چکیده
The adsorptive stripping voltammetric detection of nickel and cobalt in water samples at metal film electrodes has been extensively studied. In this work, a novel, environmentally friendly, metal-free electrochemical probe was constructed for the ultra-trace determination of Ni2+ in water samples by Adsorptive Cathodic Stripping Voltammetry (AdCSV). The electrochemical platform is based on the adsorptive accumulation of Ni2+ ions directly onto a glassy carbon electrode (GCE) modified with dimethylglyoxime (DMG) as chelating agent and a Nafion-graphene (NGr) nanocomposite to enhance electrode sensitivity. The nafion-graphene dimethylglyoxime modified glassy carbon electrode (NGr-DMG-GCE) shows superior detection capabilities as a result of the improved surface-area-to-volume ratio and enhanced electron transfer kinetics following the incorporation of single layer graphene, while limiting the toxic effects of the sensor by removal of the more common mercury, bismuth and lead films. Furthermore, for the first time the NGr-DMG-GCE, in the presence of common interfering metal ions of Co2+ and Zn2+ demonstrates good selectivity and preferential binding towards the detection of Ni2+ in water samples. Structural and morphological characterisation of the synthesised single layer graphene sheets was conducted by Raman spectrometry, HRTEM and HRSEM analysis. The instrumental parameters associated with the electrochemical response, including accumulation potential and accumulation time were investigated and optimised in addition to the influence of DMG and graphene concentrations. The NGr-DMG-GCE demonstrated well resolved, reproducible peaks, with RSD (%) below 5% and a detection limit of 1.5 µg L-1 for Ni2+ reduction at an accumulation time of 120 s., the prepared electrochemical sensor exhibited good detection and quantitation towards Ni2+ detection in tap water samples, well below 0.1 mg L-1 set by the WHO and EPA standards. This comparable to the South African drinking water guidelines of 0.15 mg L-1.
منابع مشابه
Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid
In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...
متن کاملDETERMINATION OF ULTRA-TRACE AMOUNTS OF COBALT BY ADSORPTIVE DIFFERENTIAL PULSE VOLTAMMETRY USING ACDA (2-AMINOCYCLOPENTENE- 1-DITHIOCARBOXYLIC ACID)
The present work describes a selective, rapid and sensitive method for the determination of cobalt using the adsorptive differential pulse voltammetry technique. The method is based on the accumulation of Co(II) complex with 2-aminocyclopentene-1-dithiocarboxylic acid on a hanging mercury drop electrode, followed by measurement of the current of the adsorbed complex. The effects of experimental...
متن کاملLabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes
The development of a dedicated automated sequential-injection analysis apparatus for anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (AdSV) is reported. The instrument comprised a peristaltic pump, a multiposition selector valve and a home-made potentiostat and used a mercury-film electrode as the working electrodes in a thin-layer electrochemical detector. Programming o...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملAn Electrochemical Sensor Based on Nickel Oxides Nanoparticle/ Graphene Composites for Electrochemical Detection of Epinephrine
The combination of graphene and nickel oxide nanoparticles yields nanostructured electrochemical sensor formed a novel kind of structurally uniform and electrocatalytic activity material. In cyclic voltammetry studies, in the presence of epinephrine, nickel oxide / graphene composite modified electrode shows a significantly higher current response for epinephrine oxidation. Based on differenti...
متن کامل