Validity and reliability of measurement of capillary refill time in children: a systematic review.

نویسندگان

  • Susannah Fleming
  • Peter Gill
  • Caroline Jones
  • James A Taylor
  • Ann Van den Bruel
  • Carl Heneghan
  • Matthew Thompson
چکیده

BACKGROUND Most guidelines recommend the use of capillary refill time (CRT) as part of the routine assessment of unwell children, but there is little consensus on the optimum method of measurement and cut-off time. METHODS We searched Medline (from 1948), Embase (from 1980) and CINAHL (from 1991) to June 2014 to identify studies with information on the normal range of CRT in healthy children, the validity of CRT compared with reference standard measures of haemodynamic status, reliability and factors influencing measurement of CRT, such as body site, pressing time and temperature. FINDINGS We included 21 studies on 1915 children. Four studies provided information on the relationship between CRT and measures of cardiovascular status, 13 provided data on the normal range of CRT, 7 provided data on reliability and 10 assessed the effect of various confounding factors. In children over 7 days of age, the upper limit of normal CRT is approximately 2 s when measured on a finger, and 4 s when measured on the chest or foot, irrespective of whether the child is feverish or not. Longer pressing times and ambient temperature outside 20°C-25°C are associated with longer CRT. Evidence suggests that the use of stopwatches reduces variability between observers. INTERPRETATION We recommend use of the following standardised CRT method of measurement: press on the finger for 5 s using moderate pressure at an ambient temperature of 20°C-25°C. A capillary refill time of 3 s or more should be considered abnormal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Diagnostic Value of Capillary Refill Time for Detecting Serious Illness in Children: A Systematic Review and Meta-Analysis

IMPORTANCE Capillary refill time (CRT) is widely recommended as part of the routine assessment of unwell children. OBJECTIVE To determine the diagnostic value of capillary refill time for a range of serious outcomes in children. METHODS We searched Medline, Embase and CINAHL from inception to June 2014. We included studies that measured both capillary refill time and a relevant clinical out...

متن کامل

Are bedside features of shock reproducible between different observers?

Shock is often under-reported in children attending hospitals in developing countries. Readily obtainable features of shock (capillary refill time, temperature gradient, pulse volume, and signs of dehydration) are widely used to help prioritise management in the emergency assessment of critically ill or injured children. However, data are lacking on their validity, including, importantly, repro...

متن کامل

A Systematic Review of Psychometric Properties of Breastfeeding Self-Efficacy Scale-Short Form (BSES-SF)

Background: The breastfeeding self-efficacy is one of the psychological factors affecting the duration of breastfeeding; the Breastfeeding self-efficacy measured by the breastfeeding self-efficacy scale-short form (BSES-SF). It was validated and reliable in several studies. The current systematic review aimed to comprehensively review the validity and reliability of the BSES-SF in various versi...

متن کامل

Psychometric Properties of Breastfeeding Attrition Prediction Tool (BAPT): A Systematic Review

Background It is necessary to identify women who discontinue the breastfeeding to achieve the purpose of increasing the length of breastfeeding. To this end, Breastfeeding Attrition Prediction Tool (BAPT) has been developed. The current systematic review aimed to comprehensively review the validity and reliability of BAPT scale with different versions to give comprehensive information for autho...

متن کامل

Psychometric Properties of Tools Used for Children and Adolescents With Visual Impairments: A systematic Review Study

Objectives: The use of standard tools can show the exact effects of interventions in children and adolescents with visual impairment (CYP-VI). However, to date, no comprehensive review study has evaluated the general characteristics and psychometrics of the instruments used in CYP-VI. Therefore, the present study investigated the psychometric properties of the tools used for CYP-VI.  Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 100 3  شماره 

صفحات  -

تاریخ انتشار 2015