PURPOSE To compare dosimetric parameters of intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and tomotherapy (TOMO) in the adjuvant treatment of gastroesophageal junction (GEJ)/stomach cancer. The planning goal was to maintain high target coverage while keeping the dose to the bowel and bone marrow (BM) as low as possible. MATERIALS AND METHODS After curative surgery, 16 patients with GEJ/stomach cancer were re-planned by coplanar IMRT (five fixed beam), VMAT (double-arc), and TOMO. The dose to the planning target volume (PTV) was 45 Gy in 25 fractions. The target parameters, including the homogeneity index (HI) and conformity index (CI), and doses to the organs at risk (OARs) were analyzed. RESULTS Dosimetric parameters for PTV and OARs were comparable among the three techniques. However, TOMO provided improved conformity (CI = 0.92±0.03) and homogeneity (HI = 1.07±0.02) than IMRT (CI = 0.87±0.03; HI = 1.09±0.02; p < 0.05) and VMAT (CI = 0.86±0.03; HI = 1.09±0.02; p < 0.01). TOMO also improved dose sparing of the bowel (percentage of the volume receiving a dose of ≥ 30 Gy [V30] = 23.24±9.85) and BM (V30 = 71.66±6.15) compared with IMRT (bowel V30 = 30.02±11.74; BM V30 = 83.74±8.42; p < 0.01) and VMAT (bowel V30 = 31.88±11.59; BM V30 = 79.51±9.07; p < 0.01). CONCLUSIONS TOMO is a good option for adjuvant treatment of GEJ/stomach cancer in patients undergoing radical surgery due to its superior bowel and BM dose sparing, dose conformity and dose homogeneity; however, future studies are required to validate its clinical efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.&nbsp; Material...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017