The nationwide breast cancer screening programme using mammography has been in full operation in the Netherlands since 1997. Quality control of the screening programme has been assigned to the National Expert and Training Centre for Breast Cancer Screening. Limits are set to the mean glandular dose and the centre monitors these for all facilities engaged in the screening programme. This procedure is restricted to the determination of the entrance dose on a 5 cm thick polymethylmethacrylate (PMMA) phantom. The mean glandular dose for a compressed breast is estimated from these data. Individual breasts may deviate largely from this 5 cm PMMA breast model. Not only may the compressed breast size vary from 2 to 10 cm, but breast composition varies also. The mean glandular dose is dependent on the fraction of glandular tissue (glandularity) of the breast. To estimate the risk related to individual mammograms requires the development of a method for determination of the glandularity of individual breasts. A method has been developed to derive the glandularity using the attenuation of mammography x-rays in the breast. The method was applied to a series of mammograms at a screening unit. The results, i.e., a glandularity of 93% within the range of 0 to 1, were comparable with data in the literature. The glandularity as a function of compressed breast thickness is similar to results from other investigators using differing methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج یک کُد فرترن برای محاسبه دوز غده‌ای در ماموگرافی با استفاده از پارامترهای Sobol-Wu

Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...

متن کامل

Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code

Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...

متن کامل

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

بررسی عوامل موثر بر متوسط دوز غده ای در ماموگرافی با استفاده از کد شبیه سازی MCNPX

Background: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. Breast tissue composition is one of the factors affecting on DgN values. In this study both homogeneous and heterogeneous breast tissue is assumed and its impact on DgN values are evaluated. Methods: Homogeneous breast phantom with diffe...

متن کامل

Estimating average glandular dose in routine mammography screening using neural network

Given the extensive use of common mammography tests for screening and diagnosis of breast cancer, there are concerns over the increased dose absorbed by the patient due to the sensitivity of the breast tissue. Thus, knowing the Mean Glandular Dose (MGD) before radiation to the patient through its estimation can be helpful. For this reason, the MultiLayer Perceptron (MLP) neural network model wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 24  شماره 

صفحات  -

تاریخ انتشار 2005