Very Late Pathological Responses to Cobalt–Chromium Everolimus‐Eluting, Stainless Steel Sirolimus‐Eluting, and Cobalt–Chromium Bare Metal Stents in Humans

نویسندگان

  • Hiroyoshi Mori
  • Dheeraj R. Atmakuri
  • Sho Torii
  • Ryan Braumann
  • Samantha Smith
  • Hiroyuki Jinnouchi
  • Anuj Gupta
  • Emanuel Harari
  • Melsi Shkullaku
  • Robert Kutys
  • David Fowler
  • Maria Romero
  • Renu Virmani
  • Aloke V. Finn
چکیده

BACKGROUND The "very late" clinical outcomes for durable polymer drug-eluting stents and bare metal stents (BMSs) have been shown to be dissimilar in clinical studies. Conceptually, the long-term vascular compatibility of BMSs is still regarded to be superior to drug-eluting stents; however, no pathologic study to date has specifically addressed this issue. We evaluated the very late (≥1 year) pathologic responses to durable polymer drug-eluting stents (cobalt-chromium [CoCr] everolimus-eluting stents [EESs] and stainless steel sirolimus-eluting stents [SS-SESs]) versus BMSs (CoCr-BMSs). METHODS AND RESULTS From the CVPath stent registry, we studied a total of 119 lesions (40 CoCr-EESs, 44 SS-SESs, 35 CoCr-BMSs) from 92 autopsy cases with a duration ranging from 1 to 5 years. Sections of stented coronary segments were pathologically analyzed. Inflammation score and the percentage of struts with giant cells were lowest in CoCr-EESs (median inflammation score: 0.6; median percentage of struts with giant cells: 3.8%) followed by CoCr-BMSs (median inflammation score: 1.3 [P<0.01]; median percentage of struts with giant cells: 8.9% [P=0.02]) and SS-SESs (median inflammation score: 1.7 [P<0.01]; median percentage of struts with giant cells: 15.3% [P<0.01]). Polymer delamination was observed exclusively in SS-SESs and was associated with increased inflammatory and giant cell reactions. The prevalence of neoatherosclerosis with CoCr-EESs (50%) was significantly less than with SS-SESs (77%, P=0.02) but significantly greater than with CoCr-BMSs (20%, P<0.01). CONCLUSIONS CoCr-EESs, SS-SESs, and BMSs each demonstrated distinct vascular responses. CoCr-EESs demonstrated the least inflammation, near-equivalent healing to BMSs, and lower neointimal formation. These results challenge the belief that BMSs have superior biocompatibility compared with some polymeric coated drug-eluting stents and may have implications for future stent design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Second Generation Drug-Eluting Stents: A Review of the Everolimus-Eluting Platform

Everolimus-eluting stents (EES) represent the next generation of drug-eluting stents (DES). Important design modifications include thin strut stent backbones, less inflammatory and more biocompatible polymers, and lower drug dosing. The cobalt chromium EES fluoropolymer XIENCE V stent has been the most extensively studied of such stents. In animal models, this stent demonstrated minimal vessel ...

متن کامل

Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis.

BACKGROUND The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. METHODS AND RESULTS Study stents included BMS, paclitaxel-eluting (PES), siroli...

متن کامل

Influence of metal alloy and the profile of coronary stents in patients with multivessel coronary disease

BACKGROUND In Brazil, despite the recommendations of the Brazilian Society of Hemodynamics and Interventional Cardiology, the National Health System has not yet approved the use of drug-eluting stents. In percutaneous coronary interventions performed in the public and part of the private health care system, bare metal stents are used as the only option. Therefore, new information on bare metal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017