Comparison of 16 mm OSU‐Nag and COMS eye plaques

نویسندگان

  • Hualin Zhang
  • Frederick Davidorf
  • Yujin Qi
چکیده

OSU-NAG eye plaques use fewer sources than COMS-plaques of comparable size, and do not employ a Silastic seed carrier insert. Monte Carlo modeling was used to calculate 3D dose distributions for a 16 mm OSU-NAG eye plaque and a 16 mm COMS eye plaque loaded with either Iodine-125 or Cesium-131 brachytherapy sources. The OSU-NAG eye plaque was loaded with eight sources forming two squares, whereas the COMS eye plaque was loaded with thirteen sources approximating three isocentric circles. A spherical eyeball 24.6 mm in diameter and an ellipsoid-like tumor 6 mm in height and 12 mm in the major and minor axes were used to evaluate the doses delivered. To establish a fair comparison, a water seed carrier was used instead of the Silastic seed carrier designed for the traditional COMS eye plaque. Calculations were performed on the dose distributions along the eye plaque axis and the DVHs of the tumor, as well as the 3D distribution. Our results indicated that, to achieve a prescription dose of 85 Gy at 6 mm from the inner sclera edge for a six-day treatment, the OSU-NAG eye plaque will need 6.16 U/source and 6.82U/source for 125I and 131Cs, respectively. The COMS eye plaque will require 4.02 U/source and 4.43 U/source for the same source types. The dose profiles of the two types of eye plaques on their central axes are within 9% difference for all applicable distances. The OSU-NAG plaque delivers about 10% and 12% more dose than the COMS for 125I and 131Cs sources, respectively, at the inner sclera edge, but 6% and 3% less dose at the opposite retina. The DVHs of the tumor for two types of plaques were within 6% difference. In conclusion, the dosimetric quality of the OSU-NAG eye plaque used in eye plaque brachytherapy is comparable to the COMS eye plaque.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation for Treatment Planning Optimization of the COMS and USC Eye Plaques Using the MCNP4C Code

Introduction: Ophthalmic plaque radiotherapy using I-125 radioactive seeds in removable episcleral plaques is often used in management of ophthalmic tumors. Radioactive seeds are fixed in a gold bowl-shaped plaque and the plaque is sutured to the scleral surface corresponding to the base of the intraocular tumor. This treatment allows for a localized radiation dose delivery to the tumor with a ...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

Improved treatment planning for COMS eye plaques.

PURPOSE A recent reanalysis of the Collaborative Ocular Melanoma Study (COMS) medium tumor trial concluded that incorporating factors to account for anisotropy, line source approximation, the gold plaque, and attenuation in the Silastic seed carrier into the dose calculations resulted in a significant and consistent reduction of calculated doses to structures of interest within the eye. The aut...

متن کامل

Seed coordinates of a new COMS‐like 24 mm plaque verified using the FARO Edge

A 24 mm COMS-like eye plaque was developed to meet the treatment needs of our eye plaque brachytherapy practice. As part of commissioning, it was necessary to determine the new plaque's seed coordinates. The FARO Edge, a commercially available measurement arm, was chosen for this purpose. In order to validate the FARO Edge method, it was first used to measure the seed marker coordinates in the ...

متن کامل

Dosimetric benefit of a new ophthalmic radiation plaque.

PURPOSE To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. METHODS AND MATERIALS One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012