چکیده

OBJECTIVE To study the relation between resolution of ST segment deviation and infarct size using positron emission tomography. METHODS 45 patients with ST segment elevation acute myocardial infarction treated with thrombolysis or percutaneous coronary intervention were studied prospectively. An ECG was taken before and at (mean (SD)) 100 (45) min after reperfusion therapy. ECGs were analysed by three methods. Residual ST segment deviation, obtained from the ECG immediately after completion of reperfusion therapy, was defined by summation for each of the three methods. Relative resolution of ST segment deviation was defined as the absolute resolution divided by the ST segment deviation score at baseline x 100 (%). After 29 (14) hours, myocardial blood flow was measured with 13NH3. For each patient, the regions with a myocardial blood flow < 80% of normally perfused myocardium ( = hypoperfusion) and < 50% ( = no reflow) were automatically delineated. RESULTS Substantial differences were found between different ECG analysis methods. There were moderate correlations between the area with myocardial hypoperfusion and ST segment deviation scores at baseline and after reperfusion therapy. After reperfusion therapy, residual ST segment deviation in the single lead with maximum ST segment deviation was as good at discriminating between tertiles of myocardial damage as summed ST segment elevation. Relative ST segment resolution did not discriminate between different degrees of myocardial damage. CONCLUSIONS In the individual patient, residual ST segment deviation after reperfusion in the single lead with maximum ST segment deviation is at least as good as summed ST elevation in predicting final myocardial damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reciprocal ST-segment depression associated with exercise-induced ST-segment elevation indicates residual viability after myocardial infarction.

OBJECTIVES We evaluated the clinical significance of reciprocal ST-segment depression associated with exercise-induced ST-segment elevation for detecting residual viability within the infarcted area. BACKGROUND Although the relation between residual viability and exercise-induced ST-segment elevation has been described, there are no reports focusing on the relation between myocardial viabilit...

متن کامل

TIMI myocardial perfusion grade and ST segment resolution: association with infarct size as assessed by single photon emission computed tomography imaging.

BACKGROUND The TIMI myocardial perfusion grade (TMPG) and ST-segment resolution both reflect perfusion and are associated with mortality after thrombolysis for acute myocardial infarction. We hypothesized that these measures would also be associated with infarct size by single photon emission computed tomography (SPECT). Methods and Results- In the LIMIT AMI trial (Limitation of Myocardial Inju...

متن کامل

Quantifying the Area at Risk in Reperfused ST-Segment-Elevation Myocardial Infarction Patients Using Hybrid Cardiac Positron Emission Tomography-Magnetic Resonance Imaging.

BACKGROUND Hybrid positron emission tomography and magnetic resonance allows the advantages of magnetic resonance in tissue characterizing the myocardium to be combined with the unique metabolic insights of positron emission tomography. We hypothesized that the area of reduced myocardial glucose uptake would closely match the area at risk delineated by T2 mapping in ST-segment-elevation myocard...

متن کامل

A Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals

Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 90 8  شماره 

صفحات  -

تاریخ انتشار 2004