In vitro measurement of patellofemoral force after three types of knee replacement.

نویسندگان

  • R K Miller
  • J W Goodfellow
  • D W Murray
  • J J O'Connor
چکیده

Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20 degrees to 120 degrees of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no significant change in the PFF. After arthroplasty with a posterior-cruciate-retaining prosthesis and division of the anterior cruciate ligament, the PFF decreased in extension and increased by 20% in flexion. Implantation of a posterior stabilised prosthesis and division of both cruciate ligaments produced a decrease in the PFF in extension but maintained normal load in flexion. There was a direct relationship between the PFF and the angle made with the patellar tendon and the long axis of the tibia. The abnormalities of the patellar tendon angle which resulted from implantation of the two total prostheses explain the observed changes in the PFF and show how the mechanics of the patellofemoral joint depend upon the kinematics of the tibiofemoral articulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous in vitro measurement of patellofemoral kinematics and forces.

This study involved the development and testing of a system for the simultaneous in vitro measurement of tibiofemoral kinematics and patellofemoral kinematics and forces. Knee motion was tracked using a Vicon 370, and patellofemoral force was measured using a six degree-of-freedom transducer based on the design of Singerman et al. Using this system, twelve knee specimens were tested in supine l...

متن کامل

Immediate effect of Mulligan knee taping on pain, knee dynamic valgus, and landing kinetic in physically active female with patellofemoral pain

 Aims and background: Inappropriate kinetic and kinematic are considered as effective factors in knee injuries especially patellofemoral pain. The aim of this study was to investigate the immediate effect of Mulligan taping on knee dynamic valgus, maximum knee flexion angle, the maximum ground reaction force, time to stabilization and pain in physically active female with patellofemoral pain an...

متن کامل

Biomechanical effects of kneeling after total knee arthroplasty.

BACKGROUND Kneeling following total knee arthroplasty can be a difficult task, impairing the activities of patients to varying degrees. Little is known about the biomechanical effects of kneeling following total knee replacement. The objective of this study was to quantify the effects of kneeling on patellofemoral joint contact areas and pressures, knee joint reaction force, and patellar kinema...

متن کامل

Dynamic in vitro measurement of patellar movement after total knee arthroplasty: an in vitro study

BACKGROUND Changing the kinematic behaviour of patellar movement could be one of the reasons for anterior knee pain after implantation of a total knee arthroplasty (TKA). The aim of the current study was to measure the potential influence on patellar kinematics of patellar resurfacing during TKA. METHODS Patellar movement before and after TKA with and without patellar resurfacing was measured...

متن کامل

Comparisons of bracing and patellar taping on knee three-dimensional kinematics of women with patellofemoral pain syndrome in stance phase of running

Introduction: Patellofemoral pain syndrome (PFPS) is one of the most common knee injuries that accounted for between 25-40% of all knee problems presenting to sports medicine centers. Two treatment methods of bracing and taping are recommended in these patients that their effectiveness are unclear. The aim of this study was to evaluate the efficacy of the two treatment methods on knee three-dim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 5  شماره 

صفحات  -

تاریخ انتشار 1998