Effects of micro-arc oxidation coating on outcomes of a cementless grit-blasted tapered-wedge stem in total hip arthroplasty.

نویسندگان

  • Seung-Jae Lim
  • Sin-Hyung Park
  • Sang-Yeon So
  • Youn-Soo Park
چکیده

To evaluate the effects of micro-arc oxidation (MAO) coating on the outcomes of a grit-blasted tapered-wedge stem in total hip arthroplasty (THA), we performed a retrospective review of 141 THAs using MAO coated stem for a minimum of 5years and compared them to 219 THAs using the same geometry stem without MAO coating. Harris hip score improved from 43.7 points preoperatively to 93.9 points postoperatively. No hips were revised for aseptic loosening. Complications included one squeaking hip, one iliopsoas tendonitis, and one deep vein thrombosis. Postoperative Harris hip scores, WOMAC scores, UCLA activity scores, stem stabilities, and complication rates did not differ between the groups. After medium-term follow-up, our findings did not support the use of MAO coating on grit-blasted tapered-wedge stem to improve clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survival analysis of cementless grit-blasted titanium total hip arthroplasties.

Although about 200000 cementless Zweymüller-Alloclassic total hip arthroplasties (THAs) were carried out worldwide in the last decade, the survival analysis of these prostheses was not available in the 2000 report of the Swedish national hip arthroplasty registry. We report a prospective survivorship analysis of 200 consecutive grit-blasted cementless Alloclassic primary THAs carried out since ...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Cementless total hip arthroplasty using a threaded cup and a rectangular tapered stem. Follow-up for ten to 17 years.

We carried out a clinical and radiological review of 103 cementless primary hip arthroplasties with a tapered rectangular grit-blasted titanium press-fit femoral component and a threaded conical titanium acetabular component at a mean follow-up of 14.4 years (10.2 to 17.1). The mean Harris hip score at the last follow-up was 89.2 (32 to 100). No early loosening and no fracture of the implant we...

متن کامل

Second-Generation Versus First-Generation Cementless Tapered Wedge Femoral Stems.

Clinical outcomes of a new second-generation proximally coated, tapered wedge cementless stem were compared with those of its predecessor regarding (1) all-cause implant survivorship; (2) objective and subjective outcomes; (3) complications; and (4) radiographic features. Patients who underwent a primary total hip arthroplasty with the second-generation stem (68 hips) were compared with those w...

متن کامل

Revision hip arthroplasty in patients with a previous total hip replacement for osteonecrosis of the femoral head.

Patients with osteonecrosis of the femoral head are typically relatively young and active and often require high rates of revision after primary total hip arthroplasty. However, outcomes of revision hip arthroplasty in this patient population have rarely been reported in the literature. The authors conducted a retrospective review of 72 patients (75 hips) who underwent revision hip arthroplasty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 29 12  شماره 

صفحات  -

تاریخ انتشار 2014