Development of High-sensitivity and High-resolution Digital Mammography System ‘AMULET’

نویسندگان

  • Kaku IRISAWA
  • Takahisa ARAI
  • Hajime NAKATA
  • Tomonari SENDAI
  • Takao KUWABARA
  • Katsutoshi YAMANE
چکیده

FUJIFILM’s newly-developed ‘AMULET’, a digital mammography system, simultaneously realizes high-image quality, low-dose image acquisition and high-throughput as well as patient-oriented design. A detector mounted on AMULET directly converts X-ray signals into electronic signals to readout the electronic signals by using a uniquely developed “Direct Optical Switching” readout method in its imaging process. This detector with dual amorphous Se layers makes it possible to deliver high-definition diagnostic images consisting of 50 μm-size pixels providing the finest resolution among direct-conversion X-ray image detectors. Well-optimized Auto-Exposure-Control between the direct-conversion detector and an x-ray tube with Mo and W targets can meet the wide range of diagnostic needs from high-image quality to low-dose exposure. Moreover, ergonomic design helps to alleviate patient’s discomfort.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Average Glandular Dose and Entrance Surface Dose in Mammography

In general, dose evaluation for mammography uses average glandular dose (AGD). In mammography, entrance surface dose (ESD) is high, which is well known, but actual clinical data of ESD are not reported so much. This study investigated AGD and ESD for patients whose doses were estimated from 200 mammography examinations using European Organization for Quality-Assured Breast Screening and Diagnos...

متن کامل

Epidemiology, Prevention, Screening

Background: Over 90% of mammography machines in Japan have already become digital, however, almost three-fourths of them utilize computed radiography (CR). The majority of them necessitate hard copy diagnosis. Therefore, reliability of soft-copy interpretation of CR mammography is still controversial. The purpose of this study is to assess the usefulness and problems of soft-copy interpretation...

متن کامل

ارزیابی تطبیقی کارایی ساختار فراداده نظام‌های شناسگر دیجیتالی

The main solution to the problems of persistency and uniqueness in identification of digital objects in a web environment is provided by using digital identifiers instead of URL. The main basis of this solution is resolution mechanism that is used in digital identifier systems. Resolution is the use of indirect names instead of URLs; what worked for the DNS (Domain Name System) in stabilizing i...

متن کامل

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...

متن کامل