Diffusion- and perfusion-weighted MRI. The DWI/PWI mismatch region in acute stroke.

نویسندگان

  • T Neumann-Haefelin
  • H J Wittsack
  • F Wenserski
  • M Siebler
  • R J Seitz
  • U Mödder
  • H J Freund
چکیده

BACKGROUND AND PURPOSE Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) are relatively new MR techniques increasingly used in acute stroke. During the first hours of stroke evolution, the regions with abnormal perfusion are typically larger than the DWI lesions, and this mismatch region has been suggested to be "tissue at risk." The aim of this study was to evaluate the PWI/DWI mismatch region in acute stroke patients and find parameters indicative of both infarct progression and functional impairment. METHODS Twenty patients with nonlacunar ischemic stroke were imaged with DWI, PWI, and conventional MRI within 24 hours of symptom onset and after 1 week; in addition, the European Stroke Scale (ESS) score was recorded. With PWI, the volumes of regions with "time-to-peak" (TTP) delays of >/=2, 4, 6, 8, and 10 seconds were measured; these volumes were compared with the acute DWI lesion volumes, final infarct size, and ESS score. RESULTS In 80% of patients the acute DWI lesion was surrounded by regions with abnormal TTP delays (PWI>DWI lesion). A TTP delay of >/=6 s in the mismatch region was found to be associated with lesion enlargement between the initial and follow-up MRI scans. Lesions increased in 9 of 12 patients (75%) in whom the area with TTP delay >/=6 s was larger than the DWI lesion, but they increased in only 1 of 8 (12.5%) of the remaining patients, in whom the area with a TTP delay >/=6 s was smaller than the DWI lesion. The volume of the regions with TTP delays of >/=4 s correlated better with ESS (r=-0.88, P<0.001) than other PWI (or DWI) volumes, which indicated that a TTP delay of approximately 4 s might be the threshold for functional impairment of brain tissue. CONCLUSIONS Only patients with severe perfusion deficits in the PWI/DWI mismatch (TTP delays of >/=6 s) are at high risk of lesion enlargement. Functionally, more moderate perfusion deficits (TTP delays >/=4 and <6 s) appear to also contribute to the acute clinical deficit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do acute diffusion- and perfusion-weighted MRI lesions identify final infarct volume in ischemic stroke?

BACKGROUND AND PURPOSE An acute mismatch on diffusion-weighted MRI (DWI) and perfusion-weighted MRI (PWI) may represent the "tissue-at-risk." It is unclear which "semiquantitative" perfusion parameter most closely identifies final infarct volume. METHODS Acute stroke patients underwent DWI and PWI (dynamic-susceptibility contrast imaging) on admission (baseline), and T2-weighted imaging (T2WI...

متن کامل

Diffusion- and perfusion-weighted MRI: influence of severe carotid artery stenosis on the DWI/PWI mismatch in acute stroke.

BACKGROUND AND PURPOSE Diffusion-weighted imaging (DWI) and perfusion-weighted imaging (PWI) have been used increasingly in recent years to evaluate acute stroke in the emergency setting. In the present study, we compared DWI and PWI findings in acute stroke patients with and without severe extracranial internal carotid artery (ICA) disease. METHODS Twenty-seven patients with nonlacunar ische...

متن کامل

Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted MRI abnormalities in 117 consecutive patients with stroke symptoms.

BACKGROUND AND PURPOSE Diffusion-weighted MRI (DWI) is highly sensitive to early cerebral ischemia, but its dependence on lesion location, acuity, and etiology remains unknown. Furthermore, although a marked perfusion-weighted MRI (PWI)-DWI mismatch may exist in a subset of acute strokes, the frequency and distribution of these mismatches have never been methodically characterized in an unselec...

متن کامل

Total mismatch: negative diffusion-weighted imaging but extensive perfusion defect in acute stroke.

BACKGROUND AND PURPOSE The perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch may identify patients who benefit from thrombolysis. However, some patients exhibit a "total mismatch," ie, negative DWI but extensive PWI defect. We aimed to assess clinical and MRI data of these patients. METHODS From June 2007 to December 2008, patients with anterior circulation ischemic s...

متن کامل

Reliability of assessing percentage of diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE Emergent neurovascular imaging holds promise in identifying new and optimum target populations for thrombolysis in stroke. Recent research has focused on patients with diffusion-weighted MRI (DWI)-perfusion-weighted MRI (PWI) mismatch as a marker of tissue at risk of infarction and a means to select the most suitable candidates for thrombolysis. The present study sought t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 30 8  شماره 

صفحات  -

تاریخ انتشار 1999