Detection of hydrogen peroxide in Photosystem II (PSII) using catalytic amperometric biosensor

نویسندگان

  • Ankush Prasad
  • Aditya Kumar
  • Makoto Suzuki
  • Hiroyuki Kikuchi
  • Tomoya Sugai
  • Masaki Kobayashi
  • Pavel Pospíšil
  • Mika Tada
  • Shigenobu Kasai
چکیده

Hydrogen peroxide (H2O2) is known to be generated in Photosystem II (PSII) via enzymatic and non-enzymatic pathways. Detection of H2O2 by different spectroscopic techniques has been explored, however its sensitive detection has always been a challenge in photosynthetic research. During the recent past, fluorescence probes such as Amplex Red (AR) has been used but is known to either lack specificity or limitation with respect to the minimum detection limit of H2O2. We have employed an electrochemical biosensor for real time monitoring of H2O2 generation at the level of sub-cellular organelles. The electrochemical biosensor comprises of counter electrode and working electrodes. The counter electrode is a platinum plate, while the working electrode is a mediator based catalytic amperometric biosensor device developed by the coating of a carbon electrode with osmium-horseradish peroxidase which acts as H2O2 detection sensor. In the current study, generation and kinetic behavior of H2O2 in PSII membranes have been studied under light illumination. Electrochemical detection of H2O2 using the catalytic amperometric biosensor device is claimed to serve as a promising technique for detection of H2O2 in photosynthetic cells and subcellular structures including PSII or thylakoid membranes. It can also provide a precise information on qualitative determination of H2O2 and thus can be widely used in photosynthetic research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission

Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...

متن کامل

A sensitive photosystem II-based biosensor for detection of a class of herbicides.

We have developed a biosensor for the detection of residual triazine-, urea- and phenolic-type herbicides, using isolated photosystem II (PSII) particles from the thermophilic cyanobacterium, Synechococcus elongatus, as biosensing elements. The herbicide detection was based on the fact that, in the presence of artificial electron acceptors, the light-induced electron transfer through isolated P...

متن کامل

A biosensor for the detection of triazine and phenylurea herbicides designed using Photosystem II coupled to a screen-printed electrode.

A biosensor for the detection of triazine- and phenylurea-type herbicides was constructed using isolated Photosystem II (PS II) complexes as a biosensing element. PSII isolated from the thermophilic cyanobacterium Synechococcus elongatus was immobilized on the surface of a screen-printed sensor composed of a graphite working electrode and Ag/AgCl reference electrode deposited on a polymeric sub...

متن کامل

Production of Reactive Oxygen Species by Photosystem II as a Response to Light and Temperature Stress

The effect of various abiotic stresses on photosynthetic apparatus is inevitably associated with formation of harmful reactive oxygen species (ROS). In this review, recent progress on ROS production by photosystem II (PSII) as a response to high light and high temperature is overviewed. Under high light, ROS production is unavoidably associated with energy transfer and electron transport in PSI...

متن کامل

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...