Intracoronary thrombectomy with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution in patients with acute coronary syndrome: a prospective, randomized, controlled study.

نویسندگان

  • Gilbert Beran
  • Irene Lang
  • Wolfgang Schreiber
  • Stefan Denk
  • Thomas Stefenelli
  • Bonni Syeda
  • Gerald Maurer
  • Dietmar Glogar
  • Peter Siostrzonek
چکیده

BACKGROUND In patients with acute coronary syndrome (ACS), percutaneous coronary intervention (PCI) may cause thrombus dislodgment followed by reduced flow and impaired microcirculatory function. We prospectively compared conventional PCI to a strategy of additional pretreatment using the X-sizer thrombectomy system. METHODS AND RESULTS Sixty-six patients (51 [77%] men; 54.9+/-9.9 years) with ACS (49 with ST-elevation infarction [STEMI]) and suspected intracoronary thrombus were randomized 1:1 to pretreatment with X-sizer and conventional PCI alone. Various aspects of epicardial flow and microvascular function were studied. Baseline data were similar in both groups. Postprocedural TIMI 3 flow was obtained in 90% of X-sizer-treated patients and in 84% of controls (NS); however, corrected TIMI frame count was lower in X-sizer- treated patients (18.3+/-10.2 versus 24.7+/-14.1; P<0.05). No significant group differences were observed in final coronary flow reserve, myocardial blush grade, and myocardial dye intensity. In STEMI, the sum of ST elevation was significantly lower in X-sizer-treated patients immediately after (2.78+/-3.05 versus 6.15+/-6.32 mm; P<0.03) and 6 hours after (2.17+/-2.31 versus 4.14+/-3.7 mm; P<0.05) intervention. ST-segment resolution >50% was observed in 83% of X-sizer-treated patients and in 52% of controls (P<0.03). Multivariate analysis identified X-sizer treatment as the single independent predictor of ST-segment resolution >50% (OR 4.35; 95% CI, 1.13 to 16.9; P<0.04). Major adverse cardiac events after 30 days occurred in 2 patients in each group. CONCLUSIONS In ACS with suspected thrombus, pretreatment with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution compared with conventional PCI alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary Thrombectomy With the X-Sizer Catheter System Improves Epicardial Flow and Accelerates ST-Segment Resolution in Patients With Acute Coronary Syndrome

Background—In patients with acute coronary syndrome (ACS), percutaneous coronary intervention (PCI) may cause thrombus dislodgment followed by reduced flow and impaired microcirculatory function. We prospectively compared conventional PCI to a strategy of additional pretreatment using the X-sizer thrombectomy system. Methods and Results—Sixty-six patients (51 [77%] men; 54.9 9.9 years) with ACS...

متن کامل

X-sizer for thrombectomy in acute myocardial infarction improves ST-segment resolution: results of the X-sizer in AMI for negligible embolization and optimal ST resolution (X AMINE ST) trial.

OBJECTIVES We sought to compare, in a prospective randomized multicenter study, the effect of adjunctive thrombectomy using X-Sizer (eV3, White Bear Lake, Minnesota) before percutaneous coronary intervention (PCI) versus conventional PCI in patients with acute myocardial infarction (AMI) for <12 h and Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 to 1. The primary end point was the ...

متن کامل

Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction.

OBJECTIVES We sought to evaluate the effects of mechanical thrombectomy on myocardial reperfusion during direct angioplasty for acute myocardial infarction (AMI). BACKGROUND Embolization of thrombus and plaque debris may occur during direct angioplasty for AMI. This may lead to distal vessel or side branch occlusion and to obstructions in the microvascular system, resulting in impaired myocar...

متن کامل

Early experience with a helical coronary thrombectomy device in patients with acute coronary thrombosis.

OBJECTIVE To report our experience with a new thrombectomy device (X-SIZER(TM)) in patients with angiographically visible thrombus or total coronary occlusion in the setting of acute coronary syndromes. DESIGN A safety and feasibility study in the use of the X-SIZER during intervention in patients with acute coronary syndromes. PATIENTS 35 patients, age range 31 to 83 years (mean 60). SET...

متن کامل

A case of successful reperfusion through a combination of intracoronary thrombolysis and aspiration thrombectomy in ST-segment elevation myocardial infarction associated with an ectatic coronary artery

BACKGROUND Large thrombus burdens in ectatic coronary arteries that remain after aspiration thrombectomy can negatively impact outcomes following percutaneous coronary interventions in patients with acute myocardial infarction. CASE PRESENTATION A 53-year-old man presented with ST-segment elevation myocardial infarction (STEMI). Coronary angiography revealed an ectatic right coronary artery (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 20  شماره 

صفحات  -

تاریخ انتشار 2002