Abdominal Functional Electrical Stimulation to Assist Ventilator Weaning in Acute Tetraplegia: A Cohort Study

نویسندگان

  • Euan J. McCaughey
  • Helen R. Berry
  • Alan N. McLean
  • David B. Allan
  • Henrik Gollee
  • A.B. Johan Groeneveld
چکیده

BACKGROUND Severe impairment of the major respiratory muscles resulting from tetraplegia reduces respiratory function, causing many people with tetraplegia to require mechanical ventilation during the acute stage of injury. Abdominal Functional Electrical Stimulation (AFES) can improve respiratory function in non-ventilated patients with sub-acute and chronic tetraplegia. The aim of this study was to investigate the clinical feasibility of using an AFES training program to improve respiratory function and assist ventilator weaning in acute tetraplegia. METHODS AFES was applied for between 20 and 40 minutes per day, five times per week on four alternate weeks, with 10 acute ventilator dependent tetraplegic participants. Each participant was matched retrospectively with a ventilator dependent tetraplegic control, based on injury level, age and sex. Tidal Volume (VT) and Vital Capacity (VC) were measured weekly, with weaning progress compared to the controls. RESULTS Compliance to training sessions was 96.7%. Stimulated VT was significantly greater than unstimulated VT. VT and VC increased throughout the study, with mean VC increasing significantly (VT: 6.2 mL/kg to 7.8 mL/kg VC: 12.6 mL/kg to 18.7 mL/kg). Intervention participants weaned from mechanical ventilation on average 11 (sd: ± 23) days faster than their matched controls. CONCLUSION The results of this study indicate that AFES is a clinically feasible technique for acute ventilator dependent tetraplegic patients and that this intervention may improve respiratory function and enable faster weaning from mechanical ventilation. TRIAL REGISTRATION ClinicalTrials.gov NCT02200393.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Probing with the ventilator

Neurally adjusted ventilatory assist operates through recordings of electrical activity of the diaphragm (EAdi). Barwing and colleagues found increases in EAdi in weaning-failure patients, although the values were not significantly different from weaning-success patients. Future studies will need to carefully control for the considerable biological noise evident in EAdi recordings.

متن کامل

Abdominal functional electrical stimulation to enhance mechanical insufflation-exsufflation

CONTEXT Respiratory complications, attributed to the build-up of secretions in the airway, are a leading cause of rehospitalisation for the tetraplegic population. Previously, we observed that the application of Abdominal Functional Electrical Stimulation (AFES) improved cough function and increased demand for secretion removal, suggesting AFES may aid secretion clearance. Clinically, secretion...

متن کامل

Automatic electrical stimulation of abdominal wall muscles increases tidal volume and cough peak flow in tetraplegia.

Paralysis of the respiratory muscles in people with tetraplegia affects their ability to breathe and contributes to respiratory complications. Surface functional electrical stimulation (FES) of abdominal wall muscles can be used to increase tidal volume (V_{T}) and improve cough peak flow (CPF) in tetraplegic subjects who are able to breathe spontaneously. This study aims to evaluate the feasib...

متن کامل

Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran

Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...

متن کامل

Roles of neurally adjusted ventilatory assist in improving gas exchange in a severe acute respiratory distress syndrome patient after weaning from extracorporeal membrane oxygenation: a case report

BACKGROUND Patient-ventilator asynchrony is a major cause of difficult weaning from mechanical ventilation. Neurally adjusted ventilatory assist (NAVA) is reported useful to improve the synchrony in patients with sustained low lung compliance. However, the role of NAVA has not been fully investigated. CASE PRESENTATION The patient was a 63-year-old Japanese man with acute respiratory distress...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015