ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study

نویسندگان

  • Stefanie Van den Bremt
  • Sofie Schouwers
  • Marjan Van Blerk
  • Lieve Van Hoovels
چکیده

Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA) Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU) and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Indirect Immunofluorescence Evaluation of Antinuclear Autoantibodies on HEp-2 Cells

Indirect immunofluorescence (IIF) on human epithelial (HEp-2) cells is considered as the gold standard screening method for the detection of antinuclear autoantibodies (ANA). However, in terms of automation and standardization, it has not been able to keep pace with most other analytical techniques used in diagnostic laboratories. Although there are already some automation solutions for IIF inc...

متن کامل

Performance of an Automated Fluorescence Antinuclear Antibody Image Analyzer

BACKGROUND The gold standard for antinuclear antibody (ANA) screening is the indirect immunofluorescence (IIF) assay with human epithelial cells (HEp-2). However, a number of substantial disadvantages of manual IIF assays have highlighted the need for the automation and standardization of fluorescent ANA (FANA) testing. We evaluated the performance of EUROPattern Suite (Euroimmun AG, Germany), ...

متن کامل

Automated evaluation of ANA under real-life conditions

INTRODUCTION Visual evaluation of indirect immunofluorescence (IIF) on human epithelial-2 cells is the routine method for screening for antinuclear antibodies (ANA) in connective tissue diseases. Since visual IIF is time-consuming and subjective, automated IIF processors have been developed to offer standardised, valid and cost-efficient IIF assays. OBJECTIVE The aim of this study was to dete...

متن کامل

Next-Generation Autoantibody Testing by Combination of Screening and Confirmation—the CytoBead® Technology

Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different ...

متن کامل

Anti-nuclear antibody screening using HEp-2 cells.

The American College of Rheumatology position statement on ANA testing stipulates the use of IIF as the gold standard method for ANA screening(1). Although IIF is an excellent screening test in expert hands, the technical difficulties of processing and reading IIF slides--such as the labor intensive slide processing, manual reading, the need for experienced, trained technologists and the use of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017