Transformer Top-Oil Temperature Modeling and Simulation
نویسندگان
چکیده
The winding hot-spot temperature is one of the most critical parameters that affect the useful life of the power transformers. The winding hot-spot temperature can be calculated as function of the top-oil temperature that can estimated by using the ambient temperature and transformer loading measured data. This paper proposes the estimation of the top-oil temperature by using a method based on Least Squares Support Vector Machines approach. The estimated top-oil temperature is compared with measured data of a power transformer in operation. The results are also compared with methods based on the IEEE Standard C57.91-1995/2000 and Artificial Neural Networks. It is shown that the Least Squares Support Vector Machines approach presents better performance than the methods based in the IEEE Standard C57.91-1995/2000 and artificial neural networks. Keywords—Artificial Neural Networks, Hot-spot Temperature, Least Squares Support Vector, Top-oil Temperature.
منابع مشابه
Different Electric Vehicle Charging Strategies to avoid Reducing the Insulation Oil Lifetime of Distribution Transformers
Abstract: The widespread presence of uncontrolled electric vehicles causes overloading of distribution network equipment. One of these equipments is distribution transformer, which should pay attention to overloading and reducing lifetime of this equipment due to charging of electric vehicles. First, strategies have been proposed to investigate the effect of electric vehicle penetration level a...
متن کاملPrediction of Transformer Insulation Life with an Effect of Environmental Variables
The Hot Spot Temperature (HST) value depends on the ambient temperature, the rise in the top oil temperature (TOT) over the ambient temperature, and the rise in the winding HST over the top oil temperature. In this paper a new semi-physical model comprising of the environmental variables for the estimation of HST and loss of insulation life in transformer is proposed. The winding hot-spot tempe...
متن کاملPrevention of hot spot temperature in a distribution transformer using magnetic fluid as a coolant
A MneZn ferrite magnetic fluid (TCF-56) having 5.6 mT fluid magnetization and high pyromagnetic coefficient, (vM/vT 1⁄4 177 A/m K) has been investigated as a coolant in a 3 kW prototype transformer for overloading condition (167%). The winding temperature of a transformer submerged in magnetic fluid reaches at 396.8 K after 3 h of overloading, which is 20 K lower, when the same experiment was c...
متن کاملInvestigating the Transformer Operating Conditions for Evaluating the Dielectric Response
This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...
متن کاملPetri Net Modeling of Transformer Fault Diagnosis Process
Transformer fault diagnosis and repair is a complex task that includes many possible types of faults and demands special trained personnel. In this paper, Petri Nets are used for the simulation of transformer fault diagnosis process and the definition of the actions followed to repair the transformer. An oil thermometer and a Buchholz relay are used for transformer fault detection. Simulation r...
متن کامل