Perforation of the descending aorta by the tip of an intra-aortic balloon pump catheter.
نویسندگان
چکیده
Perforation of the proximal descending aorta occurred in a patient on intra-aortic balloon pump (IABP) support after emergency coronary intervention for acute myocardial infarction. The IABP catheter was inserted under fluoroscopic guidance into the right femoral artery without difficulty, but after 8 h on IABP support the patient went into shock with a left hemothorax. Emergency surgery was performed with cardiopulmonary bypass and a perforation of the proximal descending aorta with active bleeding was found and successfully repaired. A distorted descending aorta in which the IABP catheter was kinked, as in the aortic arch, was discovered during surgery and confirmed postoperatively with 3-dimensional computed tomography scans, particularly in the lateral view. Not only the antero-posterior but also the lateral fluoroscopic view is recommended to prevent aortic perforation by a kinked IABP catheter.
منابع مشابه
Complications of Intra - aortic Balloon Insertion and
One hundred consecutive patients considered to be candidates for intra-aortic balloon pumping (IABP) are reviewed from a standpoint of complications and difficulties encountered with balloon catheter insertion. A single attempt at positioning the balloon in the descending thoracic aorta proved successful in 73% of these patients, but the standard femoral artery approach proved difficult in 27% ...
متن کاملIntraluminal projection of descending thoracic aorta and intraaortic balloon pump catheter examined by transesophageal echocardiography in patients undergoing coronary artery bypass surgery.
The thoracic descending aorta (DTA) was examined in 57 patients undergoing coronary artery bypass grafting (41 men and 16 women: 63.0 +/- 10.6 years old) using two-dimensional transesophageal echocardiography. An intraaortic balloon pump (IABP) was instituted in ten patients. A short-axis view of DTA was examined for intraluminal projection from the diaphragm level to the aortic arch level. In ...
متن کاملA novel technique for intra-aortic balloon positioning in the intensive care unit.
Proper positioning of the intra-aortic balloon catheter is very important as an improperly placed balloon can cause problems. A balloon placed too high can block off the arch vessels, whereas one placed too low can block the renal and splanchnic vessels. We propose a simple and reliable technique to properly position the intra-aortic balloon pump (IABP) catheter without the use of any sophistic...
متن کاملThe Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملComplications of intra-aortic balloon insertion and counterpulsation.
One hundred consecutive patients considered to be candidates for intra-aortic balloon pumping (IABP) are reviewed from a standpoint of complications and difficulties encountered with balloon catheter insertion. A single attempt at positioning the balloon in the descending thoracic aorta proved successful in 73% of these patients, but the standard femoral artery approach proved difficult in 27% ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 66 4 شماره
صفحات -
تاریخ انتشار 2002