Single-reagent method for rapid determination of total bilirubin with the "CentrifiChem" Analyzer.
نویسندگان
چکیده
We report a rapid single-reagent method for determining total bilirubin with the “CentrifiChem Analyzer” (Union Carbide Corp.). The reagent is the stable 1,5-disulfonate of diazosulfanilic acid, and ethylene glycol is used as an accelerator. The reaction requires less than 5 mm. Only 25 l of serum is needed. We present precision data ( = 2.62 mg/dl, SD = .082 mg/dl, CV = 3.13%) and results (r = .998) as compared with those obtained by an automated Jendrassik-Grof method.
منابع مشابه
A bichromatic method for total bilirubin with a CentrifiChem 400.
We describe a method for the bichromatic determination of total bilirubin with a CentrifiChem 400 centrifugal analyzer with the Boehringer DPD kit. After reading the blank at 620 nm, we read the test at 550 nm. Because only one rotor is required, the analytical time for bilirubin estimations is halved. The proposed method is no more prone to interference by hemoglobin or turbidity than a conven...
متن کاملAutomated reaction-rate method for the direct determination of total serum cholesterol by use of the "CentrifiChem" parallel fast analyzer.
The direct procedure for determining serum cholesterol described by Wybenga et al. [C/in. Chem. 16, 980 (1970)] can be used to assay 29 samples in 10-mm reaction time by using the “CentrifiChem” parallel fast analyzer (Union Carbide). Commercial reference serum was used for standardization. Correlation of results with those obtained by the method of Abell et al. [J. Bio/. Chem. 195, 357 (1952)]...
متن کاملKinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.
We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-starch technique. The method for total amylase appeared to be rapid and precise (C...
متن کاملEvaluation of the ABA-100 procedure for total and direct bilirubin in serum or plasma.
We present a modified Evelyn-Malloy method, adapted to the Abbott Biochromatic Analyzer (ABA-100) for the determination of both total and direct bilirubin. It requires less than 25 mul of serum or plasma. At least 50 samples can be assayed per hour with economy of reagent consumption and the precision compares favorably with that for conventional manual methods.
متن کاملOptimized method for measuring aspartate aminotransferase activity with the CentrifiChem Analyzer, with automatic preincubation of serum.
We propose a routine method for the mechanized measurement of aspartate aminotransferase with the CentrifiChem Analyzer, which is based on the recommendations of both the International Federation of Clinical Chemistry and the Société Française de Biologie Clinique. A modification of the CentrifiChem pipettor permits simultaneous pipetting of two reagents, thus achieving automatic preincubation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 19 12 شماره
صفحات -
تاریخ انتشار 1973