Doses to internal organs for various breast radiation techniques - implications on the risk of secondary cancers and cardiomyopathy

نویسندگان

  • Jean-Philippe Pignol
  • Brian M Keller
  • Ananth Ravi
چکیده

BACKGROUND Breast cancers are more frequently diagnosed at an early stage and currently have improved long term outcomes. Late normal tissue complications induced by adjuvant radiotherapy like secondary cancers or cardiomyopathy must now be avoided at all cost. Several new breast radiotherapy techniques have been developed and this work aims at comparing the scatter doses of internal organs for those techniques. METHODS A CT-scan of a typical early stage left breast cancer patient was used to describe a realistic anthropomorphic phantom in the MCNP Monte Carlo code. Dose tally detectors were placed in breasts, the heart, the ipsilateral lung, and the spleen. Five irradiation techniques were simulated: whole breast radiotherapy 50 Gy in 25 fractions using physical wedge or breast IMRT, 3D-CRT partial breast radiotherapy 38.5 Gy in 10 fractions, HDR brachytherapy delivering 34 Gy in 10 treatments, or Permanent Breast 103Pd Seed Implant delivering 90 Gy. RESULTS For external beam radiotherapy the wedge compensation technique yielded the largest doses to internal organs like the spleen or the heart, respectively 2,300 mSv and 2.7 Gy. Smaller scatter dose are induced using breast IMRT, respectively 810 mSv and 1.1 Gy, or 3D-CRT partial breast irradiation, respectively 130 mSv and 0.7 Gy. Dose to the lung is also smaller for IMRT and 3D-CRT compared to the wedge technique. For multicatheter HDR brachytherapy a large dose is delivered to the heart, 3.6 Gy, the spleen receives 1,171 mSv and the lung receives 2,471 mSv. These values are 44% higher in case of a balloon catheter. In contrast, breast seeds implant is associated with low dose to most internal organs. CONCLUSIONS The present data support the use of breast IMRT or virtual wedge technique instead of physical wedges for whole breast radiotherapy. Regarding partial breast irradiation techniques, low energy source brachytherapy and external beam 3D-CRT appear safer than 192Ir HDR techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of the risk for the second cancers induction in healthy tissues during the radiation therapy of liver’s tumor

The aim of this study was to estimate the delivered doses to tissues and organs around the liver tumor during radiotherapy and to determine organs with a high probability of secondary induction cancers. This study was carried out using Monte Carlo method. The used Phantom, the ORNL phantom is for an adult female. The volume of the tumor is as much as 30% of the liver tissue.In the initial step...

متن کامل

Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

متن کامل

Secondary cancers during the radiotherapy of prostate cancer: a review article

Prostate cancer is the most common and second leading cause of death among men in the world. Nowadays, radiotherapy has been known as one of the most affecting methods for prostate cancer treatment. Nevertheless, radiotherapy is accompanied by the concern of developing secondary cancers by the scattered radiation to the neighbor  organs at risk. Several studies have shown that secondary cancers...

متن کامل

Radiation-induced Non-targeted Effect and Carcinogenesis; Implications in Clinical Radiotherapy

Bystander or non-targeted effect is known to be an interesting phenomenon in radiobiology. The genetic consequences of bystander effect on non-irradiated cells have shown that this phenomenon can be considered as one of the most important factors involved in secondary cancer after exposure to ionizing radiation. Every year, millions of people around the world undergo radiotherapy in order to cu...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011