Microwave-accelerated metal-enhanced fluorescence: application to detection of genomic and exosporium anthrax DNA in <30 seconds.

نویسندگان

  • Kadir Aslan
  • Yongxia Zhang
  • Stephen Hibbs
  • Les Baillie
  • Michael J R Previte
  • Chris D Geddes
چکیده

We describe the ultra-fast and sensitive detection of the gene encoding the protective antigen of Bacillus anthracis the causative agent of anthrax. Our approach employs a highly novel platform technology, Microwave-Accelerated Metal-Enhanced Fluorescence (MAMEF), which combines the use of Metal-Enhanced Fluorescence to enhance assay sensitivity and focused microwave heating to spatially and kinetically accelerate DNA hybridization. Genomic and exosporium target DNA of Bacillus anthracis spores was detected within a minute in the nanograms per microliter concentration range using low-power focused microwave heating. The MAMEF technology was able to distinguish between B. anthracis and B. cereus, a non-virulent close relative. We believe that this study has set the stage and indeed provides an opportunity for the ultra-fast and specific detection of B. anthracis spores with minimal pre-processing steps using a relatively simple but cost-effective technology that could minimize casualties in the event of another anthrax attack.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-fast pg/ml anthrax toxin (protective antigen) detection assay based on microwave-accelerated metal-enhanced fluorescence.

Rapid presymptomatic diagnosis of Bacillus anthracis at early stages of infection plays a crucial role in prompt medical intervention to prevent rapid disease progression and accumulation of lethal levels of toxin. To detect low levels of the anthrax protective antigen (PA) exotoxin in biological fluids, we have developed a metal-enhanced fluorescence (MEF)-PA assay using a combination of the M...

متن کامل

Microwave-Accelerated Plasmonics: Application to Ultra-Fast and Ultra-Sensitive Clinical Assays

In recent years our laboratory has described the favorable effects of fluorophores in close proximity to metallic nanostructures (1-6). These include, increased system quantum yields (increased detectability) and much improved fluorophore photostabilities. These effects have led to many applications of metal-enhanced fluorescence (MEF) including, improved DNA detection (7, 8), enhanced ratiomet...

متن کامل

Extraction and detection of DNA from Bacillus anthracis spores and the vegetative cells within 1 min.

The use of a combination of low-cost technologies to both extract and detect anthrax DNA from spores and vegetative cells in two steps within 1 min is described. In a cavity, microwave energy is highly focused using thin-film aluminum "bow-tie" structures, to extract DNA from whole spores within 20 s. The detection of the released DNA, from less than 1000 vegetative cells, without additional pr...

متن کامل

Microwave-Accelerated and Metal-Enhanced Fluorescence Myoglobin Detection on Silvered Surfaces: Potential Application to Myocardial Infarction Diagnosis

In this short paper, we describe a novel approach to both significantly accelerate and optically amplify fluorescence-based immunoassays. Our approach utilizes metal-enhanced fluorescence (MEF) to intrinsically optically amplify fluorescence signatures, which, when combined with the use of low-power microwaves to kinetically accelerate assays, provides for both ultrafast and ultrabright immunoa...

متن کامل

Ultra-Fast and Sensitive Detection of Non-Typhoidal Salmonella Using Microwave-Accelerated Metal-Enhanced Fluorescence (“MAMEF”)

Certain serovars of Salmonella enterica subsp. enterica cause invasive disease (e.g., enteric fever, bacteremia, septicemia, meningitis, etc.) in humans and constitute a global public health problem. A rapid, sensitive diagnostic test is needed to allow prompt initiation of therapy in individual patients and for measuring disease burden at the population level. An innovative and promising new r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 132 11  شماره 

صفحات  -

تاریخ انتشار 2007