BACKGROUND Previous studies indicate that analysis of the ST waveform of the fetal electrocardiogram provides information on the fetal response to hypoxia. We did a multicentre randomised controlled trial to test the hypothesis that intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis results in an improved perinatal outcome compared with cardiotocography alone. METHODS At three Swedish labour wards, 4966 women with term fetuses in the cephalic presentation entered the trial during labour after a clinical decision had been made to apply a fetal scalp electrode for internal cardiotocography. They were randomly assigned monitoring with cardiotocography plus ST analysis (CTG+ST group) or cardiotocography only (CTG group). The main outcome measure was rate of umbilical-artery metabolic acidosis (pH <7.05 and base deficit >12 mmol/L). Secondary outcomes included operative delivery for fetal distress. Results were first analysed according to intention to treat, and secondly after exclusion of cases with severe malformations or with inadequate monitoring. FINDINGS The CTG+ST group showed significantly lower rates of umbilical-artery metabolic acidosis than the cardiotocography group (15 of 2159 [0.7%] vs 31 of 2079 [2%], relative risk 0.47 [95% CI 0.25-0.86], p=0.02) and of operative delivery for fetal distress (193 of 2519 [8%] vs 227 of 2447 [9%], 0.83 [0.69-0.99], p=0.047) when all cases were included according to intention to treat. The differences were more pronounced after exclusion of 291 in the CTG+ST group and 283 in the CTG group with malformations or inadequate recording. INTERPRETATION Intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis increases the ability of obstetricians to identify fetal hypoxia and to intervene more appropriately, resulting in an improved perinatal outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fetal electrocardiography in labor and neonatal outcome: data from the Swedish randomized controlled trial on intrapartum fetal monitoring.

OBJECTIVE Cardiotocography plus automatic ST analysis of the fetal electrocardiography has been shown recently to reduce both the operative delivery rate for fetal distress and the cord artery metabolic acidosis rate. The purpose of this study was to analyze findings that were related to cases with a complicated/adverse neonatal outcome in the Swedish randomized controlled trial. STUDY DESIGN...

متن کامل

A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN®) for intrapartum monitoring

BACKGROUND Cardiotocography (CTG) is worldwide the method for fetal surveillance during labour. However, CTG alone shows many false positive test results and without fetal blood sampling (FBS), it results in an increase in operative deliveries without improvement of fetal outcome. FBS requires additional expertise, is invasive and has often to be repeated during labour. Two clinical trials have...

متن کامل

Cardiotocography plus ST analysis of fetal electrocardiogram compared with cardiotocography only for intrapartum monitoring: a randomized controlled trial.

OBJECTIVE To estimate the effectiveness of intrapartum fetal monitoring by cardiotocography plus ST analysis using a strict protocol for performance of fetal blood sampling. METHODS We performed a multicenter randomized trial among laboring women with a high-risk singleton pregnancy in cephalic presentation beyond 36 weeks of gestation. Participants were assigned to monitoring by cardiotocogr...

متن کامل

Use of fetal electrocardiogram for intrapartum monitoring.

INTRODUCTION Intrapartum fetal monitoring is essential for the identification of fetal hypoxia to reduce perinatal morbidity and mortality. Cardiotocography is associated with low specificity for fetal acidosis and poor perinatal outcome leading to unnecessary operative deliveries. ST waveform analysis of the fetal electrocardiogram has been shown to be a promising adjunctive intrapartum assess...

متن کامل

A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography--a randomised controlled study.

OBJECTIVE To examine whether intrapartum monitoring by means of automatic ST analysis (STAN) of fetal electrocardiography could reduce the rate of neonatal acidemia and the rate of operative intervention during labour, compared with monitoring by means of cardiotocography (CTG). DESIGN Randomised controlled trial. SETTING Labour ward in tertiary-level university hospital. SAMPLE A total o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lancet

دوره 358 9281  شماره 

صفحات  -

تاریخ انتشار 2001