Fourier transform-plasmon waveguide spectroscopy: a nondestructive multifrequency method for simultaneously determining polymer thickness and apparent index of refraction.
نویسندگان
چکیده
Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an average percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).
منابع مشابه
Variable Index of Refraction Ultrathin Films Formed from Self-Assembled Zirconium Phosphonate Multilayers: Characterization by Surface Plasmon Resonance Measurements and Polarizat ion/Modulat ion FT-IR Spectroscopy
Ultrathin (submicrometer) organic films of specified index of refraction are constructed by the sequential deposition of self-assembled zirconium phosphonate (ZP) molecular monolayers that contain two Merent bisphosphonate ions, 1,lO-decanediylbis(phosphonate) (DBP) and 4,4azobis[(p-phenylene)methylenelbis(phosphonate) (AZO). By varying the ratio of DBP to AZO monolayers in the ZP multilayer fi...
متن کاملSelf-referenced spectroscopy using plasmon waveguide resonance biosensor
A plasmon waveguide resonance (PWR) sensor is designed, fabricated, and tested for self-referenced biosensing. The PWR sensor is able to support two different polarizations, TM and TE. The TM polarization has a large sensitivity to variations in the background refractive index while the TE polarization is more sensitive to the surface properties. The ability of the PWR sensor to simultaneously ...
متن کاملNear-Infrared Surface Plasmon Resonance Measurements of Ultrathin Films. 2. Fourier Transform SPR Spectroscopy
The application of surface plasmon resonance (SPR) measurements to the study of ultrathin organic films adsorbed onto gold surfaces utilizing near-infrared (NIR) excitation from a Fourier transform (FT) spectrometer is described. The FT-SPR experiment measures the NIR reflectivity spectrum from a prism/gold film/water assembly at a fixed angle of incidence approximately 1-2° greater than the cr...
متن کاملPractical analysis of polymers with depth varying compositions using Fourier transform infrared photoacoustic spectroscopy (plenary)
Fourier transform infrared photoacoustic spectroscopy can be used as a nondestructive method to probe the molecular composition of materials as a function of depth into the sample. This is done by varying the thickness of the surface layer being analyzed, which can be as great as some tens of micrometers, depending on optical and thermal properties.Computational methods are described to process...
متن کاملApplication of scanning angle Raman spectroscopy for determining the location of buried polymer interfaces with tens of nanometer precision.
Near-infrared scanning angle (SA) Raman spectroscopy was utilized to determine the interface location in bilayer films (a stack of two polymer layers) of polystyrene (PS) and polycarbonate (PC). Finite-difference-time-domain (FDTD) calculations of the sum square electric field (SSEF) for films with total bilayer thicknesses of 1200-3600 nm were used to construct models for simultaneously measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 86 24 شماره
صفحات -
تاریخ انتشار 2014