IOLMaster keratometry for the calculation of toric intraocular lens power and orientation

نویسنده

  • Wilfried Bissmann
چکیده

In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially for the implantation of toric lenses, as to what instrument system is more suitable: a topography system, a manual keratometer or the keratometer of the IOLMaster on the basis of the reproducibility of individual measurements. The reproducibility of the measurement of the spherical equivalent (SE) with the IOLMaster – here the mean difference between the minimum and maximum SE of 3 individual measurements per eye – was 0.09 ± 0.06 D [0 – 0.52]. The deviations within one measurement series were very low: in 79% the deviations were lower than 0.125 D, in 93% lower than 0.25 D, in 99% lower than 0.50 D and in 100% lower than 1.00 D. The reproducibility of the measurement of the power of the astigmatism – here the mean difference between the minimum and maximum astigmatism of 3 individual measurements – was 0.21 ± 0.17 D [0 – 1.35]. The deviations of the measured values in the measuring series were low here also: 43% lay within 0.125 D, 74% within 0.25 D, 92% within 0.50 D and 99% within 1.00 D. The reproducibility of the axis measurements was dependent on the power of the astigmatism. IOLMaster keratometry for the calculation of toric intraocular lens power and orientation Wilfried Bissmann, PhD, Marcus Blum, MD, Kathleen S. Kunert, MD The deviation between the maximum and minimum axial values for astigmatisms from 0.76 D were smaller than 5 degrees on average and smaller than 2 degrees on average from 2.5 D. In regard to the clinical requirements the IOLMaster demonstrated its suitability for measuring exact basic data for the calculation and implantation of toric intraocular lenses. The importance of toric intraocular lenses for the correction of higher astigmatism, and of cataract patients in particular, is growing. In the past 10 years the IOLMaster has become established as the gold standard for biometry and IOL power measurement and helps to obtain optimal refractive outcomes after intraocular lens implantation. While only the mean corneal power is of significance in the IOL power calculation of spherical lenses, the power and position of the corneal astigmatism plays an additional important role in the implantation of toric lenses. To determine the basic data for the calculation of a toric IOL, manual and automatic keratometers and topography systems are available. A retrospective clinical study is aimed at clarifying to what extent keratometry with the IOLMaster clinically provides sufficiently exact values for calculating the power of a toric intraocular lens, as well as an adequately exact axis for the implantation. The measured values obtained are compared with the clinical requirements. 1) Wilfried Bissmann, Carl Zeiss Meditec AG 2) Marcus Blum und Kathleen S. Kunert, HELIOS Klinikum Erfurt, Eye Clinic

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power

PURPOSE To determine whether the total corneal refractive power (TCRP) value, which is based on measurement of both anterior and posterior corneal astigmatism, is effective for toric intraocular lens (IOL) calculation with AcrySof(®) Toric IOLs. PATIENTS AND METHODS A consecutive series of cataract surgery cases with AcrySof toric IOL implantation was studied retrospectively. The IOLMaster(®)...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators

PURPOSE To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. MATERIALS AND METHODS Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values...

متن کامل

Surgically Induced Astigmatism Assessment

The article “Surgically Induced Astigmatism Assessment: Comparison Between Three Corneal Measuring Devices” by Ofir et al.1 was effective in demonstrating equivalence between three anterior corneal measuring devices (Lenstar LS900, Haag-Streit, Koeniz, Switzerland; IOLMaster 500, Carl Zeiss Meditec, Dublin, CA; and Atlas topographer, Carl Zeiss Meditec) by assessing the vectorial astigmatism ch...

متن کامل

Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation

BACKGROUND To evaluate and compare the astigmatism prediction errors taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens (IOL) implantation. METHODS Phacoemulsification with toric Precizon IOL implantation was performed in 41 eyes with corneal astigmatism (range, 1 to 5 diopters (D)) determined by IOLMaster and SimK on Pentacam. Preoperative c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010