Elevated Positive End-Expiratory Pressure Decreases Cardiac Index in a Rhesus Monkey Model

نویسندگان

  • Patrick A. Ross
  • Robinder G. Khemani
  • Sarah S. Rubin
  • Anoopindar K. Bhalla
  • Christopher J. L. Newth
چکیده

RATIONALE Clinicians are often concerned that higher positive end-expiratory pressure (PEEP) will decrease cardiac index (CI). PEEP affects CI through multiple inter-related mechanisms. The adult Rhesus monkey is an excellent model to study cardiopulmonary interaction due to similar pulmonary and chest wall compliances to human infants. OBJECTIVE Our goal was to examine the impact of increasing PEEP on CI in Rhesus monkeys as a model for critically ill children. METHODS Prospective, experimental animal study. Nine healthy anesthetized, intubated Rhesus monkeys were allowed to breathe spontaneously at a PEEP of 0, 5, 10, and 15 cm H2O while CI was measured with an ultrasonic Doppler (USCOM). MEASUREMENTS AND MAIN RESULTS Cardiac index decreased between PEEP levels of 5 and 15 cm H2O. The mean decrease in CI for the entire cohort of monkeys was 18% (p < 0.01) with a range of -11 to 49%. Stroke volume and oxygen delivery also decreased between PEEP levels of 5 and 15 cm H2O (p < 0.01). CONCLUSION Between PEEP levels of 5 and 15 cm H2O, there was a decrease in CI, stroke volume, and oxygen delivery in intubated Rhesus monkeys. A plausible mechanism is that over-distention of normally compliant lungs at increased PEEP resulted in decreased preload to the right ventricle, outweighing the potentially beneficial decrease in left ventricular afterload or pulmonary vascular resistance. Further investigation is warranted, particularly in children with lung injury, who have historically benefited from increased PEEP levels without over-distention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimisation of positive and expiratory pressure for maximal delivery of oxygen to tissues using oesophageal Doppler ultrasonography.

OBJECTIVE To assess oesophageal Doppler ultrasonography as a convenient means of optimising positive end expiratory pressure for maximal delivery of oxygen to tissues. DESIGN Measurements of blood flow, arterial oxygen saturation, and cardiac output by thermodilution (when available) at baseline and at 20-30 minutes after each incremental increase (2.5-5.0 cm H2O) in positive and expiratory p...

متن کامل

Influence of ventilation strategies on survival in severe controlled hemorrhagic shock.

OBJECTIVE To investigate the effect of different ventilation settings on hemodynamic stability in severe controlled hemorrhagic shock. DESIGN Prospective, randomized, controlled animal study. SETTING Research laboratory in a university hospital. SUBJECTS Approximately 35-45 kg domestic pigs. INTERVENTIONS Twenty-four domestic pigs were bled 45 mL/kg (estimated 65% of their calculated bl...

متن کامل

Myocardial Infarction in a Rhesus Monkey

Myocardial necrosis can be result from a number of causes including nutritional deficiencies, chemical and plant toxins, ischemia and metabolic disorder. The outcome of myocardial necrosis varies depending on the extent of the damage (Donald 2001, Jubb 1993, Radostits 1994, Vanvaleet 1986). Myocardial infarction without demonstrable of atherosclerosis were reported in a rhesus macaque (Gonder 1...

متن کامل

The prophylactic effect of different levels of positive end-expiratory pressure on the incidence rate of atelectasis after cardiac surgery: A Randomized Controlled Trial

&nbsp;&nbsp;&nbsp; Background: The use of positive end-expiratory pressure (PEEP) can have an important role as one of the ways to prevent and treat atelectasis, but it seems that there is still no consensus about its beneficial level. The aim of this study was to determine the effect of different levels of PEEP on the incidence of atelectasis after heart surgery. &nbsp;&nbsp; Methods: This is...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014