On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

نویسندگان

  • Maojun Gong
  • Kenneth R Wehmeyer
  • Patrick A Limbach
  • Francisco Arias
  • William R Heineman
چکیده

Previous reports describing sample stacking on microchip capillary electrophoresis (microCE) have regarded the microchip channels as a closed system and treated the bulk flow as in traditional capillary electrophoresis. This work demonstrates that the flows arising from the intersection should be investigated as an open system. It is shown that the pressure-driven flows into or from the branch channels due to bulk velocity mismatch in the main channel should not be neglected but can be used for liquid transportation in the channels. On the basis of these concepts, a sample preconcentration scheme was developed in a commercially available single-cross glass chip for microCE. Similar to field-amplified stacking injection in traditional CE, a low conductivity sample buffer plug was introduced into the separation channel immediately before the negatively charged analyte molecules were injected. The detection sensitivity was improved by 94-, 108-, and 160-fold for fluorescein-5-isothiocyanate, fluorescein disodium, and 5-carboxyfluorescein, respectively, relative to a traditional pinched injection. The calibration curves for fluorescein and 5-carboxyfluorescein demonstrated good linearity in the concentration range (1-60 nM) investigated with acceptable reproducibility of migration time and peak height and area ratios (4-5% RSD). This preconcentration scheme will be of particular significance to the practical use of microCE in the emerging miniaturized analytical instrumentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line sample preconcentration by large-volume sample stacking with an electroosmotic flow pump (LVSEP) in microscale electrophoresis.

This review highlights on-line sample preconcentration by large-volume sample stacking with an electroosmotic flow pump (LVSEP) in microscale electrophoresis. LVSEP requires only a hydrodynamic sample injection into the whole capillary/microchannel and a constant voltage application, i.e., without polarity switching, providing an efficient sensitivity enhancement with a relatively easy experime...

متن کامل

Integration of various stacking processes in carrier ampholyte-based capillary electrophoresis.

Field-enhanced sample stacking, field-enhanced sample injection as well as electrokinetic supercharging have been successfully integrated in carrier ampholyte-based capillary electrophoresis. Through the analysis of different test sample mixtures, it has been shown that the carrier ampholyte-based background electrolytes, in spite of their very low conductivity, allow efficient online preconcen...

متن کامل

Development of a Microfluidic Device for Performing Sample Preconcentration and Capillary Electrophoresis Separation

We report on a microfabricated device for sample preconcentration and capillary electrophoresis (CE) separation in a glass microchip. The device allows highly efficient anion-selective preconcentration to be performed with a micro-nanomicrochannel structure. An integrated cross channel enables gate-injection of the preconcentrated sample into the analysis channel for CE separation. Sample preco...

متن کامل

Single-step Capillary Electrophoresis for Field-amplified Sample Stacking

We developed a novel single-step capillary electrophoresis (SSCE) scheme for field-amplified sample stacking (FASS) by using a hydrophilic material polymethyl methacrylate (PMMA) microchannel chip. The capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure of the microchannel. Through the combined action of stop valves and air vents, both...

متن کامل

Recent progress of online sample preconcentration techniques in microchip electrophoresis.

Microchip electrophoresis (MCE) has been advanced remarkably by the applications of several separation modes and the integration with several chemical operations on a single planer substrate. MCE shows superior analytical performance, e.g., high-speed analysis, high resolution, low consumption of reagents, and so on, whereas low-concentration sensitivity is still one of the major problems. To o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 11  شماره 

صفحات  -

تاریخ انتشار 2006