The impact of glenoid labrum thickness and modulus on labrum and glenohumeral capsule function.

نویسندگان

  • Nicholas J Drury
  • Benjamin J Ellis
  • Jeffrey A Weiss
  • Patrick J McMahon
  • Richard E Debski
چکیده

The glenoid labrum is an integral component of the glenohumeral capsule's insertion into the glenoid, and changes in labrum geometry and mechanical properties may lead to the development of glenohumeral joint pathology. The objective of this research was to determine the effect that changes in labrum thickness and modulus have on strains in the labrum and glenohumeral capsule during a simulated physical examination for anterior instability. A labrum was incorporated into a validated, subject-specific finite element model of the glenohumeral joint, and experimental kinematics were applied simulating application of an anterior load at 0 deg, 30 deg, and 60 deg of external rotation and 60 deg of glenohumeral abduction. The radial thickness of the labrum was varied to simulate thinning tissue, and the tensile modulus of the labrum was varied to simulate degenerating tissue. At 60 deg of external rotation, a thinning labrum increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 10.5% average strain) and anterior band (increased 7.5% average strain). These results suggest a cause-and-effect relationship between age-related decreases in labrum thickness and increases in labrum pathology. A degenerating labrum also increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 15.5% strain) and anterior band (increased 10.4% strain). This supports the concept that age-related labrum pathology may result from tissue degeneration. This work suggests that a shift in capsule reparative techniques may be needed in order to include the labrum, especially as activity levels in the aging population continue to increase. In the future validated, finite element models of the glenohumeral joint can be used to explore the efficacy of new repair techniques for glenoid labrum pathology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part I: Ultrasound anatomy and examination technique

The glenohumeral joint is a spherical articulation with a remarkable range of motion in several planes and decreased stability. The maintenance of joint stability is influenced by the functioning of specific muscle groups in the shoulder region, a complex system of ligaments reinforcing the joint capsule, and the labrum which augments the glenoid fossa. Lesions of the aforementioned structures ...

متن کامل

Superior Glenoid Labrum Displacement with Humeral Head Translation

INTRODUCTION: The stability of the glenohumeral joint (GHJ) is dependent upon passive stabilizing mechanisms such as the glenoid labrum and long head of the biceps (LHB) tendon. The labrum improves GHJ stability by increasing the glenoid concavity, and the contiguous structure of the labrum and LHB tendon may increase tension on the labrum during superior humeral translations which may contribu...

متن کامل

Factors Expressed in an Animal Model of Anteroinferior Glenohumeral Instability

BACKGROUND There is little information on the molecular factors important in healing and changes that occur in the glenoid labrum in response to injury. Using a novel animal model of acute anterior shoulder dislocation, this study characterizes the factors expressed in the glenoid labrum in response to injury and correlates their expression to glenohumeral stability. PURPOSE To study the resp...

متن کامل

Intracapsular origin of the long head of the biceps tendon with glenoid avulsion of the glenohumeral ligaments.

An 18-year-old woman presented with a history of recurrent glenohumeral dislocations involving her right dominant shoulder. Physical examination suggested physiologic hyperlaxity and anterior instability. Magnetic resonance arthrography demonstrated an anomalous intracapsular origin of the long head of the biceps tendon (LHBT), with normal-appearing LHBT in the intertubercular groove. Diagnosti...

متن کامل

Chapter 24 Shoulder Instability and Rotator Cuff Tears

Anatomy Shoulder stability is the end result of the shoulder stabilizing structures working properly together. The constraints on shoulder motion can be divided into static stabilizers and dynamic stabilizers (Table 1). Static stability is chiefly maintained by joint congruency, the labrum, and the shoulder ligaments. The glenohumeral joint is a ball and shallow socket joint with a constant mis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 132 12  شماره 

صفحات  -

تاریخ انتشار 2010