Hypoplasia of the aortic root. The problem of aortic valve replacement.
نویسندگان
چکیده
We report a technique for the enlargement of a hypoplastic aortic root by an operation whereby the hypoplastic aortic root has been so enlarged by the insertion of a Dacron fabric gusset that it will accommodate a size 9A or larger Starr-Edwards prosthesis. Our experience in five patients is described. No matter what type of valve is used for replacement of a diseased aortic valve, and no matter what improved designs of valvular prosthesis are ultimately developed, it will be necessary (in the particular group described) to enlarge the aortic ring to accommodate a size which will function correctly without causing left ventricular outflow obstruction.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملAortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملتعویض دریچه آئورت: مقایسه روش متداول و روش جدید
Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 25 3 شماره
صفحات -
تاریخ انتشار 1970