Electrophysiological alterations after mechanical circulatory support in patients with advanced cardiac failure.
نویسندگان
چکیده
BACKGROUND Recognizing that mechanical circulatory support with a left ventricular assist device (LVAD) induces changes in myocardial structure and contractile function, we examined whether there are changes in ventricular conduction and/or repolarization among failing human hearts after LVAD implantation. METHODS AND RESULTS We examined 12-lead electrocardiograms before surgery, immediately after LVAD placement, and at a delayed (>1 week) postoperative time point in 23 patients who were receiving LVAD support for refractory heart failure. The immediate effects of hemodynamic unloading via LVAD placement included a decrease in QRS duration from 117+/-6 to 103+/-6 ms (P<0.01), an increase in absolute QT duration from 359+/-6 to 378+/-8 ms (P<0.05), and an increase in the heart rate-corrected QT interval (QTc) from 379+/-10 to 504+/-11 ms (P<0.01). None of these immediate changes were observed among 22 patients undergoing routine coronary artery bypass grafting. With sustained cardiac unloading via LVAD support, there was a marked decrease in the QTc from 504+/-11 to 445+/-9 ms (P<0.001). Studies in isolated cardiac myocytes, obtained at the time of transplantation, confirmed that delayed decreases in heart rate-adjusted QTc were the result of decreases in action potential duration after LVAD support. CONCLUSIONS Acute electrocardiogram responses to LVAD placement demonstrate the dependence of QRS and QT duration on load in the failing human heart. Delayed decreases in QTc and action potential duration reflect reversal of electrophysiologic remodeling in the failing heart. Shortening of the action potential duration likely contributes to the improved cellular contractile performance observed after sustained LVAD support.
منابع مشابه
Diff'rent strokes, different folks: advanced heart failure's changing outlook.
S ince the first heart transplant was performed 45 years ago, the field of advanced heart failure has grown and evolved at a hurried pace. In the United States, ≈2300 heart transplants are now performed every year. 1 Mechanical circulatory support device implants are likely to eclipse trans-plantation in the very near future. 2 More important to the broader population of patients living with he...
متن کاملMechanical Circulatory Support Devices for Acute Right Ventricular Failure.
Right ventricular (RV) failure remains a major cause of global morbidity and mortality for patients with advanced heart failure, pulmonary hypertension, or acute myocardial infarction and after major cardiac surgery. Over the past 2 decades, percutaneously delivered acute mechanical circulatory support pumps specifically designed to support RV failure have been introduced into clinical practice...
متن کاملAdvances in Mechanical Circulatory Support Mechanical Circulatory Support for Advanced Heart Failure Patients and Technology in Evolution
After nearly 50 years of clinical development, durable mechanical circulatory support (MCS) devices are widely available for patients with advanced heart failure. The field of circulatory support has matured dramatically in recent years, thanks to the advent of smaller, rotary pumps. The resulting transition away from older pulsatile devices has been swift. Accelerated use of continuous-flow le...
متن کاملنتایج کاربرد بالون پمپ داخل آئورت در بیماران جراحی قلبIntra-Aortic Ballon Pump Outcome in Cardiac Surgical Patients
Background & Aim: Intra-aortic ballon pump(IABP) is a mechanical device that has become an accepted treatment modality for patients with severely compromised hemodynamics. The present retrospective study was undertaken to identify the major survival and nonsurvival determinants of patients who were in need of intra-aortic ballon pump support after cardiac surgery. Patients & Methods: Th...
متن کاملExperience of ECMO in Primary Graft Dysfunction after Orthotopic Heart Transplantation
BACKGROUND Primary graft dysfunction is the main cause of early mortality after heart transplantation. Mechanical circulatory support has been used to treat this syndrome. OBJECTIVE Describe the experience with extracorporeal membrane oxygenation to treat post-transplant primary cardiac graft dysfunction. METHODS Between January 2007 and December 2013, a total of 71 orthotopic heart transpl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 11 شماره
صفحات -
تاریخ انتشار 2001