[Influence of body mass index on coronary artery opacification in 64-slice CT angiography].

نویسندگان

  • L Husmann
  • S Leschka
  • T Boehm
  • L Desbiolles
  • T Schepis
  • P Koepfli
  • O Gaemperli
  • B Marincek
  • P Kaufmann
  • H Alkadhi
چکیده

PURPOSE To evaluate the influence of the body mass index (BMI) on coronary artery opacification in 64-slice CT. MATERIAL AND METHODS Sixty-two patients retrospectively underwent ECG-gated 64-slice CT coronary angiography (tube potential 120 kV, tube current time product 650 mAs) after intravenous injection of 80 ml of iodinated contrast agent (320 mg/ml, 5 ml/s). Attenuation values (HU) were measured and contrast-to-noise ratios (CNR) were calculated in the right coronary artery (RCA) and left main artery (LMA). The CNR was defined as the difference between the mean attenuation in the vessel and the mean attenuation in the perivascular fat tissue divided by the image noise in the ascending aorta. The height and weight of the patients at the time of the CT scan were recorded and the BMI was calculated. RESULTS The mean BMI was 26.2 +/- 3.2 kg/m (2) (range 19.7 - 32.2 kg/m (2)), the mean attenuation in the LMA was 330 +/- 64 HU, and the mean attenuation in the RCA was 309 +/- 68 HU. The CNR in the LMA was 16.7 +/- 3.8, and the CNR in the RCA was 15.9 +/- 3.6. The image noise in the ascending aorta significantly correlated with the BMI (r = 0.36, p < 0.01). A weak negative correlation was found between the BMI and LMA attenuation (r = - 0.28, p < 0.05), whereas no significant correlation was found for the RCA (r = - 0.21, p = 0.12). A significant negative correlation was found between the BMI and the CNR in the RCA (r = - 0.41, p < 0.05) and the LMA (r = - 0.47, p < 0.001). CONCLUSION With constant scan parameters and a constant contrast medium amount, the CNR in both coronary arteries decreases while the BMI increases. This implies a modification of previously standardized and fixed examinations with respect to individually adapted protocols with variable parameters for CT coronary angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between coronary plaque 64-slice spiral CT characteristics and risk factors of coronary artery disease patients in Chinese Han population and Mongolian

UNLABELLED Objective : To compare the coronary atherosclerotic plaque 64-slice spiral CT characteristics and the risk factors of Han (in Inner Mongolia) and Mongolian coronary artery disease patients. Metho d s: The plaques of 126 Mongolian and 269 Han patients were analyzed by 64-slice spiral CT coronary angiography. Their gender, age, height, body mass, the history of hypertension, diabetes, ...

متن کامل

Giant aneurysm of the right sinus of Valsalva causing right ventricular outflow obstruction.

Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 2010;26:591–7. 13. Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O et al. Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggeri...

متن کامل

64-slice CT for diagnosis of coronary artery disease: a systematic review.

PURPOSE The purpose of this systematic review was to assess the accuracy of 64-slice CT coronary angiography for the diagnosis of coronary artery disease. METHODS We attempted to identify all published trials in all languages that used 64-slice CT to diagnose coronary artery disease. Results of 64-slice CT coronary angiography were compared with invasive coronary angiography or intravascular ...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 178 10  شماره 

صفحات  -

تاریخ انتشار 2006