Leakage reduction for the Siemens ModuLeaf

نویسنده

  • R. Alfredo Siochi
چکیده

The Moduleaf, an add-on miniature multileaf collimator (MMLC) for the Siemens Oncor linear accelerator, provides high resolution field shaping with a maximum inter-leaf leakage dose of 1.50% at 6 MV. However, beyond the maximum treatment field size, the distribution of leakage and scatter along the y axis is different from that of the x axis, with maximum leakage values of 1.53% and 0.39%, respectively. Such differences can not be modeled in the Pinnacle treatment planning system. Also, within the 10 cm x 12 cm treatment region, leakage from the crack between closed leaf ends was 3.76%. To resolve these issues, gaps in the Moduleaf frame were filled with lead sheets, and the Siemens MLC was operated in MLC mode, rather than bank mode, so that a rectangle of 10.4 cm x 11 cm was formed with the MLC leaves closed behind the Y jaws, whose opening was 10.4 cm. This significantly reduced the difference between the leakage patterns in the x and y directions, with maximum leakage doses of 0.43% outside the treatment region and 1.67% near the crack between abutting Moduleaf leaves. The modification also reduced the mean square error between Pinnacle profiles and measured profiles in the tail region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and reduction of peripheral dose from leakage radiation on Siemens primus accelerators in electron therapy mode

In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height along applicator and of lateral distance from applicator body. Relative to ce...

متن کامل

Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators

BACKGROUND One of the standard equipment in medical linear accelerators is multi-leaf collimators (MLCs); which is used as a replacement for lead shielding. MLC's advantages are a reduction of the treatment time, the simplicity of treatment, and better dose distribution. The main disadvantage of MLC is the radiation leakages from the edges and between the leaves. The purpose of this study was t...

متن کامل

Calculation of Leakage in Water Supply Network Based on Blind Source Separation Theory

The economic and environmental losses due to serious leakage in the urban water supply network have increased the effort to control the water leakage. However, current methods for leakage estimation are inaccurate leading to the development of ineffective leakage controls. Therefore, this study proposes a method based on the blind source separation theory (BSS) to calculate the leakage of water...

متن کامل

Optimal Control Pressure for Leakage Minimization in Water Distribution Systems Using Imperialist Competitive Algorithm

One of the key factors affecting leakage in water distribution systems is network pressure management by putting Pressure Reduce Valves (PRV) in the flow path and optimal regulation of these vales in water networks. This study aimed at investigating optimal pressure management problems so as to minimize leakage in water distribution networks. To do so, an approach was proposed for both optimal ...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009