The anatomical evaluation of the dental arches using cone beam computed tomography - an investigation of the availability of bone for placement of mini-screws

نویسندگان

  • Feng Pan
  • Chung H Kau
  • Hong Zhou
  • Nada Souccar
چکیده

OBJECTIVE To assess the amount of maxillary and mandibular inter-radicular bone mass and determine the most reliable mini-screw placement sites. MATERIALS AND METHODS Retrospective Cone Beam Computed Tomography (CBCT) images of 40 Angle Class I subjects (20 females, 20 males, aged 16 to 32) were obtained. Measurements on the buccal (BI), medial (MI) and lingual (LI) sides of the inter-radicular spaces were taken at 0, 1, 2, 3, 4, 5 mm from the cemento-enamel junction (CEJ) in an apical direction. RESULTS The male and female BI scores ranged from 2.99±0.73 mm to 6.18±1.03 mm and 2.69±0.84 mm to 6.21±1.22 mm respectively. The male and female MI scores ranged from 1.36±0.38 mm to 4.50±0.99 and 1.53±0.66 to 4.77±1.99 mm respectively. LI scores ranged from 2.37±0.70 to 6.47±1.0 mm and 2.45±0.56 mm and 6.66±1.33 mm respectively. In both maxillary and mandibular arch, the inter-radicular space increased in the apical direction except for the buccal and medial inter-radicular spaces between the maxillary first and second molars. CONCLUSION The medial inter-radicular spaces are the decisive parameter for mini-screw placement. In the maxillary arch, regions between central and lateral incisors, lateral incisor and canine, first and second molars are not viable for mini-screw insertion. The residual inter-radicular regions are proper for implantation at 3 mm above the CEJ. In the mandible, the regions between incisors and canines are too narrow for mini-screw insertion and the reliable sites for mini-screws are regions between premolars, molars or first molar and second premolar at 2 mm below the CEJ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of neurovascular anatomical variations in maxillary anterior region in cone beam computed tomography images

Introduction: Incisive foramen in the maxilla is the oral terminus of the nasopalatine canal. This region is important in implantology, Therefore, the aim of this study was to investigate the  neurovascular anatomical variations in the maxillary anterior region, observed on cone beam computed tomography (CBCT) images. Materials &Methods: In this cross-sectional study, maxillary CBCT ima...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Evaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran

BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013