Impact of post-implant dosimetric parameters on the quality of life of patients treated with low-dose rate brachytherapy for localised prostate cancer: results of a single-institution study

نویسندگان

  • Antonello Veccia
  • Orazio Caffo
  • Giovanni Fellin
  • Salvatore Mussari
  • Francesco Ziglio
  • Francesca Maines
  • Luigi Tomio
  • Enzo Galligioni
چکیده

BACKGROUND To assess the relationship between dosimetric parameters and the quality of life (QL) outcomes of patients with low-intermediate-risk localised prostate cancer (LPC) treated with low-dose-rate brachytherapy (LDR-BT). MATERIALS AND METHODS We evaluated the participants in two consecutive prospective studies of the QL of patients treated with LDR-BT for LPC. QL was evaluated by means of a patient-completed questionnaire assessing non functional [physical (PHY) and psychological (PSY) well-being, physical autonomy (POW), social relationships (REL)] and functional scales [urinary (URI), rectal (REC), and sexual (SEX) function]; a scale for erectile function (ERE) was included in the second study. Urethra (D10 ≤ 210 Gy) and rectal wall constraints (V100 ≤ 0.5 cc) were used for pre-planning dosimetry and were assessed with post planning computerized tomography one month later for each patient. RESULTS QL was assessed in 251 LPC patients. Dosimetry did not influence the non-functional scales. As expected, a progressive impairment in sexual and erectile function was reported one month after LDR-BT, and became statistically significant after the third year. Rectal function significantly worsened after LDR-BT, but the differences progressively decreased after the 1-year assessment. Overall urinary function significantly worsened immediately after LDR-BT and then gradually improved over the next three years. Better outcomes were reported for V100 rectal wall volumes of ≤ 0.5 cc and D10 urethra values of ≤ 210 Gy. CONCLUSIONS The findings of this study show that dosimetric parameters influence only functional QL outcomes while non-functional outcomes are only marginally influenced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of body mass index on dosimetric quality in low-dose-rate prostate brachytherapy

PURPOSE Low-dose-rate (LDR) brachytherapy has been established as an effective and safe treatment option for men with low and intermediate risk prostate cancer. In this retrospective analysis, we sought to study the effect of body mass index (BMI) on post-implant dosimetric quality. MATERIAL AND METHODS After institutional approval, records of patients with non-metastatic prostate cancer trea...

متن کامل

Hemiablative Focal Low Dose Rate Brachytherapy: A Phase II Trial Protocol

BACKGROUND The objective of focal brachytherapy (BT) is to provide effective prostate cancer control for low-risk disease but with reduced genitourinary, gastrointestinal and sexual side effects in a cost-effective way. OBJECTIVE The aim of this study is to describe a phase II study examining technical and dosimetric feasibility and toxicity, quality of life changes, and local control with po...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Updating the Planar Patterson-Parker Table for Ir-192 and Cs-137 Brachytherapy Sources Using the Most Recent TG-43U1 Recommended Dosimetric Parameters

Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation ...

متن کامل

Correlations of post-implant regional dosimetric parameters at 24 hours and one month, with clinical results of low-dose-rate brachytherapy for localized prostate cancer

Purpose To evaluate the correlations of post-implant regional dosimetrics at 24 hours (24 h) and 1 month after implant procedures, with clinical outcomes of low-dose-rate (LDR) brachytherapy for localized prostate cancer. Material and methods Between January 2008 and December 2014, 130 consecutive patients treated for localized prostate cancer, receiving definitive iodine-125 (125I) brachythe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015