Correcting AUC for Measurement Error
نویسندگان
چکیده
Diagnostic biomarkers are used frequently in epidemiologic and clinical work. The ability of a diagnostic biomarker to discriminate between subjects who develop disease (cases) and subjects who do not (controls) is often measured by the area under the receiver operating characteristic curve (AUC). The diagnostic biomarkers are usually measured with error. Ignoring measurement error can cause biased estimation of AUC, which results in misleading interpretation of the efficacy of a diagnostic biomarker. Several methods have been proposed to correct AUC for measurement error, most of which required the normality assumption for the distributions of diagnostic biomarkers. In this article, we propose a new method to correct AUC for measurement error and derive approximate confidence limits for the corrected AUC. The proposed method does not require the normality assumption. Both real data analyses and simulation studies show good performance of the proposed measurement error correction method.
منابع مشابه
Simulation of Rainfall - Runoff Events by Applying Phase Differences Diagrams and Correcting Effective Rainfall Components
The conversion of rainfall to runoff in basins includes nonlinear relations between the complex interactions of various hydrological processes. In this study, without considering of predetermined structure, relationship between input and output system was derived individually from the nature of the data recorded. Also, the phase difference occurred between rainfall and runoff signals using c...
متن کاملOne-point Goppa Codes on Some Genus 3 Curves with Applications in Quantum Error-Correcting Codes
We investigate one-point algebraic geometric codes CL(D, G) associated to maximal curves recently characterized by Tafazolian and Torres given by the affine equation yl = f(x), where f(x) is a separable polynomial of degree r relatively prime to l. We mainly focus on the curve y4 = x3 +x and Picard curves given by the equations y3 = x4-x and y3 = x4 -1. As a result, we obtain exact value of min...
متن کاملMultiple imputation to correct for measurement error in admixture estimates in genetic structured association testing.
OBJECTIVES Structured association tests (SAT), like any statistical model, assumes that all variables are measured without error. Measurement error can bias parameter estimates and confound residual variance in linear models. It has been shown that admixture estimates can be contaminated with measurement error causing SAT models to suffer from the same afflictions. Multiple imputation (MI) is p...
متن کاملComparison of Stress-Hemoconcentration Correction Techniques for Stress-Induced Coagulation
When examining stress effects on coagulation, arithmetic correction is typically used to adjust for concomitant hemoconcentration but may be inappropriate for coagulation activity assays. We examined a new physiologically relevant method of correcting for stress-hemoconcentration. Blood was drawn from healthy men (N = 40) during baseline, mental stress, and recovery, and factor VII activity (FV...
متن کاملCorrecting Measurement Error Bias in Interaction Models with Small Samples
Several methods have been suggested to estimate non-linear models with interaction terms in the presence of measurement error. Structural equation models eliminate measurement error bias, but require large samples. Ordinary least squares regression on summated scales, regression on factor scores and partial least squares are appropriate for small samples but do not correct measurement error bia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2015