Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography.

نویسندگان

  • P Acar
  • Z Saliba
  • P Bonhoeffer
  • D Sidi
  • J Kachaner
چکیده

OBJECTIVE To apply three dimensional echocardiography to describe the geometric profile of the Amplatzer and Cardioseal occluders after deployment for closure of atrial septal defect. METHODS 20 patients (mean (SD) age, 14 (5) years) were enrolled for transcatheter closure of a secundum atrial septal defect with the Amplatzer occluder (10) or with the Cardioseal occluder (10). The two populations were matched for the stretched diameter of the defect (mean 18 (6) mm). The profile of the two occluders was examined. RESULTS Transoesophageal echocardiography did not show any residual shunts after Amplatzer occluder deployment, whereas three patients had a small residual leak after Cardioseal deployment. One patient had transient atrioventricular block with the Amplatzer device. The mean surface area of the Amplatzer occluder was 6.9 (2) cm(2), and that of the Cardioseal device 5.4 (3) cm(2) (p = 0.03). The mean volume of the Amplatzer occluder was 9.2 (1) cm(3), while that of the Cardioseal occluder was 3.5 (1) cm(3) (p < 0.0001). From the three dimensional views, the Cardioseal occluder looked like a flat square after deployment whereas the Amplatzer occluder took up a ball shape in the atrial cavity. CONCLUSIONS Three dimensional views by multiplane transoesophageal echocardiography allow a realistic in vivo description of atrial septal occluders. The Amplatzer occluder, with its high geometric profile, allows complete closure of large atrial septal defects but with some risk of mechanical complications. Use of the Cardioseal device, with its small surface coverage and high residual shunt rate, should be limited to transcatheter closure of a patent foramen ovale or small atrial septal defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices.

Transcatheter closure for atrial septal defect (ASD) and patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulant therapy. A potential complication is thrombus formation on the device after implantation. From February 2001 to June 2003, 66 patients with atrial communication were treated successfully with the Amplatzer device (16 septal and 20 PFO occluders) or ...

متن کامل

Amplatzer occluder versus CardioSEAL/STARFlex occluder: a meta-analysis of the efficacy and safety of transcatheter occlusion for patent foramen ovale and atrial septal defect.

OBJECTIVE Percutaneous transcatheter occlusion has benefited thousands of patients suffering from patent foramen ovale and atrial septal defect. However, no general agreement has been reached on the superiority among occluders. Thus, a meta-analysis between the two most commonly adopted types of occluders was conducted. METHODS The literature review has identified relevant studies up to May, ...

متن کامل

Transcatheter closure of perimembranous ventricular septal defects with Amplatzer occluder assessed by real-time three-dimensional echocardiography.

We report our initial experience in two patients using real-time three-dimensional echocardiography to assess perimembranous ventricular septal defect and device morphology and their relation with contiguous cardiac structure. Defect size and rims as well as device position and profile were displayed from the three-dimensional "en face" views. We think that real-time three-dimensional echocardi...

متن کامل

Changes in Serum Natriuretic Peptide Levels after Percutaneous Closure of Small to Moderate Ventricular Septal Defects

Background. B-type natriuretic peptide has been shown to be a very sensitive and specific marker of heart failure. In this study, we aimed to investigate the effect of percutaneous closure of ventricular septal defects with Amplatzer septal occluders on brain natriuretic peptide levels. Methods. Between 2008 and 2011, 23 patients underwent successfully percutaneous ventricular septal defect clo...

متن کامل

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 2001