Assessment of walking, running, and jumping movement features by using the inertial measurement unit.

نویسندگان

  • Yin-Shin Lee
  • Chin-Shan Ho
  • Yo Shih
  • Su-Yu Chang
  • Füle János Róbert
  • Tzyy-Yuang Shiang
چکیده

PURPOSE To observe various modes of lower limb locomotion, an inertial measurement unit (IMU) was used. Digital signals were used to identify signal characteristics that help to distinguish among locomotion modes and intensity levels. METHODS A wireless IMU was installed on the outside of shoes and three forms of locomotion (walking, running, and jumping) were assessed at two intensity levels (low and high) to observe the acceleration, foot angular velocity variations, and characteristics of the curve variations in the anteroposterior, mediolateral, and superior-inferior directions. RESULTS Most interactions between intensity and locomotion were statistically significant, except for the acceleration in the anteroposterior direction and on the horizontal plane. In addition, as the intensity increased, the values of all the parameters increased. Thus, both the acceleration values and range of angular velocity variation can be used to distinguish the intensity levels. Moreover, the results indicated that the angular velocity in the frontal axis, which is the sequence of the plantar/dorsiflexion movements, can also be used to identify different locomotion. CONCLUSIONS Uniaxial acceleration or the range of angular velocity variation could be used to identify locomotion intensities, whereas the characteristics of the uniaxial angular velocity curve could be used to identify the locomotion modes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of the Effective Components in the PDR Positioning Method Based on Detecting the User’s Movement Mode Using Smartphone Sensors

The purpose of this paper is to evaluate and improve the accuracy of indoor positioning using smartphone sensors based on Pedestrian Dead Reckoning (PDR) method. In some specific situations, such as fires or power outages that disable infrastructure-based positioning techniques, using PDR method based on smartphone sensors that perform positioning continuously is a good solution.This paper focu...

متن کامل

Walking Distance Estimation Using Walking Canes with Inertial Sensors

A walking distance estimation algorithm for cane users is proposed using an inertial sensor unit attached to various positions on the cane. A standard inertial navigation algorithm using an indirect Kalman filter was applied to update the velocity and position of the cane during movement. For quadripod canes, a standard zero-velocity measurement-updating method is proposed. For standard canes, ...

متن کامل

Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sess...

متن کامل

Detecting Huntington Patient Using Chaotic Features of Gait Time Series

Huntington's disease (HD) is a congenital, progressive, neurodegenerative disorder characterized by cognitive, motor, and psychological disorders. Clinical diagnosis of HD relies on the manifestation of movement abnormalities. In this study, we introduce a mathematical method for HD detection using step spacing. We used 16 walking signals as control and 20 walking signals as HD. We took a s...

متن کامل

Concurrent Validity of Accelerations Measured Using a Tri-Axial Inertial Measurement Unit while Walking on Firm, Compliant and Uneven Surfaces

Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walkin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Gait & posture

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2015