Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance

نویسندگان

  • Vanessa M Ferreira
  • Stefan K Piechnik
  • Erica Dall’Armellina
  • Theodoros D Karamitsos
  • Jane M Francis
  • Robin P Choudhury
  • Matthias G Friedrich
  • Matthew D Robson
  • Stefan Neubauer
چکیده

BACKGROUND T2w-CMR is used widely to assess myocardial edema. Quantitative T1-mapping is also sensitive to changes in free water content. We hypothesized that T1-mapping would have a higher diagnostic performance in detecting acute edema than dark-blood and bright-blood T2w-CMR. METHODS We investigated 21 controls (55 ± 13 years) and 21 patients (61 ± 10 years) with Takotsubo cardiomyopathy or acute regional myocardial edema without infarction. CMR performed within 7 days included cine, T1-mapping using ShMOLLI, dark-blood T2-STIR, bright-blood ACUT2E and LGE imaging. We analyzed wall motion, myocardial T1 values and T2 signal intensity (SI) ratio relative to both skeletal muscle and remote myocardium. RESULTS All patients had acute cardiac symptoms, increased Troponin I (0.15-36.80 ug/L) and acute wall motion abnormalities but no LGE. T1 was increased in patient segments with abnormal and normal wall motion compared to controls (1113 ± 94 ms, 1029 ± 59 ms and 944 ± 17 ms, respectively; p < 0.001). T2 SI ratio using STIR and ACUT2E was also increased in patient segments with abnormal and normal wall motion compared to controls (all p < 0.02). Receiver operator characteristics analysis showed that T1-mapping had a significantly larger area-under-the-curve (AUC = 0.94) compared to T2-weighted methods, whether the reference ROI was skeletal muscle or remote myocardium (AUC = 0.58-0.89; p < 0.03). A T1 value of greater than 990 ms most optimally differentiated segments affected by edema from normal segments at 1.5 T, with a sensitivity and specificity of 92 %. CONCLUSIONS Non-contrast T1-mapping using ShMOLLI is a novel method for objectively detecting myocardial edema with a high diagnostic performance. T1-mapping may serve as a complementary technique to T2-weighted imaging for assessing myocardial edema in ischemic and non-ischemic heart disease, such as quantifying area-at-risk and diagnosing myocarditis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T1-mapping accurately detects acute myocardial edema: a comparison to T2-weighted cardiovascular magnetic resonance imaging

Background T2-weighted cardiovascular magnetic resonance (CMR) is commonly used to detect myocardial edema. T1-mapping is also sensitive to changes in free water content and is quantitative, obviating the need for a presumed normal reference region to detect changes within affected myocardium. We hypothesized that T1-mapping using the novel sequence Shortened Modified Look-Locker Inversion Reco...

متن کامل

Native T1-mapping detects the location, extent and patterns of acute myocarditis without the need for gadolinium contrast agents

BACKGROUND Acute myocarditis can be diagnosed on cardiovascular magnetic resonance (CMR) using multiple techniques, including late gadolinium enhancement (LGE) imaging, which requires contrast administration. Native T1-mapping is significantly more sensitive than LGE and conventional T2-weighted (T2W) imaging in detecting myocarditis. The aims of this study were to demonstrate how to display th...

متن کامل

Assessment of intramyocardial hemorrhage by T1-weighted cardiovascular magnetic resonance in reperfused acute myocardial infarction

BACKGROUND Intramyocardialhemorrhage (IMH) reflects severe reperfusion injury in acute myocardial infarction. Non-invasive detection of IMH by cardiovascular magnetic resonance (CMR) may serve as a surrogate marker to evaluate the effect of preventive measures to reduce reperfusion injury and hence provide additional prognostic information. We sought to investigate whether IMH could be detected...

متن کامل

Diagnostic Accuracy of 3.0‐T Magnetic Resonance T1 and T2 Mapping and T2‐Weighted Dark‐Blood Imaging for the Infarct‐Related Coronary Artery in Non–ST‐Segment Elevation Myocardial Infarction

BACKGROUND Patients with recent non-ST-segment elevation myocardial infarction commonly have heterogeneous characteristics that may be challenging to assess clinically. METHODS AND RESULTS We prospectively studied the diagnostic accuracy of 2 novel (T1, T2 mapping) and 1 established (T2-weighted short tau inversion recovery [T2W-STIR]) magnetic resonance imaging methods for imaging the ischem...

متن کامل

Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarction

BACKGROUND Current cardiovascular magnetic resonance (CMR) methods, such as late gadolinium enhancement (LGE) and oedema imaging (T2W) used to depict myocardial ischemia, have limitations. Novel quantitative T1-mapping techniques have the potential to further characterize the components of ischemic injury. In patients with myocardial infarction (MI) we sought to investigate whether state-of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012