A dual-slice k-t approach for highly accelerated flow MRI

نویسندگان

  • Daniel Giese
  • Tobias Schaeffter
  • Sebastian Kozerke
چکیده

Background Phase contrast MRI has limited practical value in clinical applications due to its inherently long scan times [Kilner,JCMR’07]. Parallel imaging[Pruessmann, MRM’01] and spatio-temporal constrained reconstruction techniques[Tsao,MRM’03] have been shown beneficial[Baltes,MRM’05]. Dual slice approaches have shown advantages as compared to standard SENSE when multiple and sufficiently separated slices are acquired[Breuer, MRM’10]. We present a combination of dual slice excitation with undersampled flow imaging by modifying the k-t SENSE reconstruction framework to include sensitivity information in through-slice direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving cardiac cine MRI on 3T using 2D k-t accelerated auto-calibrating parallel imaging

Background Recently, 3D cine has gained attention due to its capability for single breath-hold volumetric measurement [1]. Nonetheless, conventional 2D cine maintains two intrinsic advantages, namely, its superior blood-myocardium contrast owing to blood in-flow effects and reduced SSFP banding artifacts with more localized slice-by-slice shimming. These advantages are more prominent at high fi...

متن کامل

The use of k-t PCA accelerated dual-venc 3D flow MRI to assess hemodynamics before and after flow diverting stent implantation in cerebral aneurysm models

Background Hemodynamic parameters are known to play a crucial role in the growth and rupture of intracranial aneurysms [Appanaboyina IntJNumerMethodsFluids2008]. Flow diverting stents have emerged as an alternative to coiling by using fine meshes to divert flow away from the aneurysm sac to promote thrombus formation and remodeling of the aneurysm while keeping side branches and perforating art...

متن کامل

Combination of Compressed Sensing and Parallel Imaging with Respiratory Motion Correction for Highly-Accelerated First- Pass Cardiac Perfusion MRI

INTRODUCTION: First-pass cardiac perfusion MRI requires fast data acquisition to achieve an appropriate combination of temporal resolution, spatial resolution and spatial coverage for clinical studies [1]. We have recently presented a combination of compressed sensing and parallel imaging (k-t SPARSE-SENSE) to highly accelerate perfusion studies by jointly exploiting sparsity in the combined sp...

متن کامل

Analysis of spatiotemporal fidelity in quantitative 3D first-pass perfusion cardiovascular magnetic resonance

BACKGROUND Whole-heart first-pass perfusion cardiovascular magnetic resonance (CMR) relies on highly accelerated image acquisition. The influence of undersampling on myocardial blood flow (MBF) quantification has not been systematically investigated yet. In the present work, the effect of spatiotemporal scan acceleration on image reconstruction accuracy and MBF error was studied using a numeric...

متن کامل

Highly-Accelerated First-Pass Cardiac Perfusion MRI Using Compressed Sensing and Parallel Imaging

INTRODUCTION: First-pass cardiac perfusion MRI is a promising modality for the assessment of coronary artery disease. Recently developed dynamic parallel imaging techniques, such as k-t SENSE [1] and k-t GRAPPA [2], can be used to perform up to 10-fold accelerated perfusion imaging by exploiting the difference in coil sensitivities and spatio-temporal correlations. Such techniques can be used t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012